C – DC 12 V Direct current application
Caution: Exclusively for charging 12 V
batteries!
Instructions for charging an
accumulator:
a) Put the Economy switch to the "OFF"
position.
b) Prepare the accumulator for charging:
c) Disconnect the accumulator terminals.
d) Remove all caps from the fluid filling
opening.
e) Add distilled water to the maximum
level (if required).
f) Measure the specific weight of the
accumulator fluid using an acetometer
and calculate the loading time
according to the table on the right.
g) The specific weight for fully charging
the accumulator should be 1.26 to
1.28. It is recommended that this be
checked every hour.
h) Using the accumulator cables, connect
the poles of the accumulator to the equivalent poles of the DC direct current
power point of the generator: + on + and - on - !
i) Check that all cables have been connected correctly and press the DC direct
current protection to the "ON" position.
3 – Stopping the engine
e) Switch all connected equipment off and remove the plug(s) from the power point
on the generator.
f) Put the engine switch to the "STOP" position.
g) Close the fuel cock, putting it in the " OFF" position.
h) Turn the venting button on the tank cap to the closed position
(counterclockwise).

Special conditions

The maximum capacity of the generator is calculated under normal operating
conditions. If the generator is used under special conditions, for example:
Use at a great height;
-
Use under extreme temperatures; or
-
Use in extremely wet conditions.
-
The maximum capacity of the generator will be reduced. Contact your supplier for
additional information.
37