1 – Oil safety system
If the oil level falls below the lowest level, the engine will stop
automatically. You must add oil and restart the engine.
2 – Engine switch (ENG.SW)
The engine switch switches the ignition system
" ON" – the ignition system is switched on,
the engine can be started.
"STOP" (OFF) – the ignition system is switched off.
The engine will not operate/it will stop.
3 – Economy switch
If the Economy button is set to "ON", the engine speed will be
adjusted to the connected load. The result is less noise and
consumption.
4 – 12 V protection (DC PROTECTOR)
The DC 12 V protection switches the power consumption off if
the load exceeds the maximum values.
Reduce the connected load to within the maximum values
indicated if the protection switches the engine off and then
switch the protection on again by
pressing the black button.
5 - Venting button on tank cap
The tank cap is equipped with a venting button.
OPEN
CLOSE
Before starting the engine, the venting button must be turned
clockwise from the closed position to the OPEN position.
This prevents the fuel tank from creating a vacuum, which
would prevent the fuel from running through properly. As soon
as the engine is switched off, close the venting button by turning it
counterclockwise. During transport and storage, the venting button must always be
shut completely.
6 – Fuel cock
If you open the fuel cock (ON), the fuel supply
to the carburettor is opened. By closing this fuel cock (OFF),
the supply is cut off.