MICRO SWITCH™ BX Series
SPECIAL CONDITIONS FOR SAFE USE
Honeywell explosion-proof switches are designed specifically
for use in hazardous location applications. The BX enclosure is
sealed for protection against corrosion, water, dust and oil as
defined in NEMA 1, 3, 4, 4X, 6, 13, and IP67 (per IEC60529). The
temperature rating for these products depends upon the seal
material used. Products using a fluorosilicone seal have a rating
of -40 °C [-40 °F] to 70 °C [158 °F]. Products using a fluorocar-
bon seal have a rating of -12 °C [10 °F] to 70 °C [158 °F]. MICRO
SWITCH™ BX switches are rated according to the electrical rat-
ings detailed in Table 1.
Table 1. Electrical Ratings: 10 A cont.
ac voltage
Single Pole
Break
Make
120
60
240
30
480
15
1.5
600
12
1.2
A300/120V
A300/240V
dc voltage
Make & Break Inductive
120
0.25
240
0.15
Q300/125V
0.55
Q300/250V
0.27
These products meet the following Protection Classes along with
complying with Essential Health and Safety Standards as men-
tioned in Table 2.
Table 2. Certifications
Certifica-
IECEx
ATEX
tion
Certificate
IECEx SIR
SIRA
number
07.0102X
00ATEX1037X
II 2 GD
II 2 GD
Ex d IIC T6 Gb
Ex d IIC T6 Gb
Ex tb IIIC T85°C
Ex tb IIIC T85°C
Protection
Db
Db
Class
-12°C < Tamb < +70°C (Fluorocarbon Seal)
-40°C < Tamb < +70°C (Fluorosilicone Seal)
IEC 60079-
EN 60079-
0:2011
0:2012
IEC 60079-
EN 60079-
Health
1:2007
1:2007
and Safety
Standards
IEC 60079-
EN 60079-
31:2013
31:2013
6
sensing.honeywell.com
Double Pole
Break
Make
6
30
3
3
15
1.5
7.5
.75
6
6
60
6
30
3
Resistive
0.80
0.40
INMETRO
EAC
НАНИО
«ЦСВЭ» РОСС
TÜV 14.0556 X
RU.0001.11ГБ05
Ex d IIC T6 Gb
1Ex d IIC T6 Gb
Ex tb IIIC T85°C
Ex tb IIIC T85°C
Db
Db
IP6X
ГОСТ Р
ABNT NBR
МЭК 60079-0-
IEC 60079-
0:2008
2011
ГОСТ
ABNT NBR
IEC 60079-
IEC 60079-1-
1:2009
2011
ABNT NBR
ГОСТ Р
IEC 60079-
МЭК 60079-31
31:2011
2010
ABNT NBR
IEC 60529:2009
The maximum construction gap (ic) is less than that required by
Table 2 of EN/IEC60079-1:2007, clause 5.2.2 as detailed below
in Table 3.
The equipment has a non-conducting coating and may generate
an ignition-capable level of electrostatic charges under certain
extreme conditions. The user should ensure that the equipment
is not installed in a location where it may be subjected to external
conditions (such as high pressure steam) that might cause a
build up of electrostatic charges on non-conducting surfaces.
Additionally, cleaning of the equipment should be done with a
damp cloth.
Table 3. Flame path measurements
Power
Flame path
factor
Push rod & bearing
.35
.35
Bearing & housing
.35
.35
BX with conduit types 1/2-14NPT, 3/4-14NPT also meet the North
.30
American Hazardous Locations Designation: NEMA 7 - Class I,
.30
Groups B, C and D; NEMA 9 - Class II, Groups E, F and G and
comply with UL Standard: UL 894, CSA Standard: C22.2 No. 25-
1966, C22.2 No. 30-M1986.
The BX is ideal for outdoor use or in adverse environments where
a combination of explosion-proof plus sealing requirements are
needed. To comply with explosion proof requirements the BX
has flame paths within the housing, which cool exploding gases
below the ignition temperature before they reach explosive gases
surrounding the housing. Flame paths on the BX are (1) an ex-
tended plunger between the switch cavity and head and (2) the
cover-housing threads on the front of the switch.
MOUNT, ADJUST, WIRE
MOUNTING
Note mounting dimension drawings for hole locations (Fig. 9,
page 3). The BX is directly interchangeable with the LSX explo-
sion-proof limit switches: Adapter plate is not required.
ADJUSTING INSTRUCTIONS
To give flexibility in application, the user can perform the adjust-
ments described below in any order before wiring the unit.
ACTUATOR HEAD
The actuator head may be positioned in any of four directions.
1.
Loosen the four captive head screws.
2.
Place head in the desired position.
3.
Securely tighten the four screws to 1,4 Nm to 1,8 Nm [12 in-
lb to 16 in-lb] (Figure 1).
REVERSING THE ROLLER LEVER
Except for the offset roller levers, the roller arm may be reversed
to face the roller to the inside or outside of the arm.
PK 80148
ISSUE 15
Max. gap
Comment
0,076 mm
Cylindrical spigot joint
0,02 mm
Cylindrical spigot joint