Beta 1498/2A Mode D'emploi page 10

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
INSTRUCTIONS FOR USE
ISTRUZIONI PER L'USO
CHARGE CYCLES OF BATTERY CHARGER
The following charge cycles for this battery charger have been specially developed to optimize the
charge of all commercially available battery types. The numerous construction technologies for the
batteries that are currently available in the market require different charging curves to ensure correct
and complete charging. This battery charger extends the lives of batteries because it provides each with
the proper charge cycle.
The battery charger has been designed to test the status of the battery both before and during charge,
and report any defective connection between the battery charger and the battery to charge.
First battery status diagnosis step: "A1"
First charging step: "Deep discharge recovery"
Second charging step: "soft I"
Third charging step: "I"
Fourth charging step: "UO"
Fifth charging step: "Recovery"
Second battery status diagnosis step: "A2"
Sixth charging step: "U"
Seventh charging step: "Up"
10
STEP
CYCLE
The battery charger tests the state of charge of the
battery to charge.
The battery charger starts charging using a pulse
current until the battery reaches optimal voltage
and current levels, so that it can start the second
charging step.
The battery is charged at a reduced, constant cur-
rent.
The battery is charged at a constant current until it
reaches its maximum voltage.
The battery is charged at a stabilized voltage until
the current reaches minimum values.
The battery is charged deeply at a constant cur-
rent and increasing voltage, so that the charge
capacity of the battery can be boosted.
The battery charger tests the state of efficiency of
the charged battery.
Holding charge at a reduced, constant voltage
Holding charge with pulses of current (provided
non-stop).
EN
I

Publicité

Table des Matières
loading

Table des Matières