SPECIFICATIONS
GENERAL SPECIFICATIONS
Description:
Dremel Glue Gun
Model number 910
Glue
temperature
• low (LO)
-
• high (HI)
165°C
Glue stick Ø
7 mm
Protection
Class
/II
EXTENSION CORDS
Use completely unrolled and safe extension
cords with a capacity of at least 5 Amps.
ASSEMBLY
GENERAL
The glue gun is intended for the quick gluing of
clean, dry and grease-free materials with glue
heated to its melting point.
PICTURE 1a/1b
1.
Nozzle
2.
Glue stick
3.
Feed trigger
4.
Stand
5.
Temperature switch
PICTURE 1c
6.
On/off switch with indicator light
7.
Detachable cord
8.
Stand release button
9.
Exchangeable nozzle
SWITCHING ON/OFF
SWITCHING ON:
Plug Dremel Glue Gun into a standard 230 V
electrical outlet.
Models 910, 920 and 930:
Once the glue gun is plugged in, it is on
and heating.
920
930
940
105°C
105°C
-
-
165°C
195°C
7 mm
7 mm
11/12 mm
/II
/II
/II
USE
Dual Temperature Glue Gun Model 930:
Adjust switch (5) to low or high temperature
setting to turn the Glue Gun on. Consult
with glue stick package to determine
appropriate temperature.
Model 940:
Connect the power cord to the glue gun.
Switch the glue gun on with the main
switch. Indicator light (6) will let you know
the glue gun is on and heating.
SWITCHING OFF:
Pull the mains plug (models 910, 920 and
930).
Switch the unit ON/OFF with switch (6;
model 940). Pull the mains plug.
Allow the unit to cool completely before storing.
The hot nozzle can cause damage.
GETTING STARTED
PREPARATIONS FOR GLUING
The surfaces to be glued must be clean, dry
and free of grease. Roughen smooth surfaces
before gluing. DO NOT USE INFLAMMABLE
SOLVENTS FOR CLEANING! The ambient
temperature and the work piece to be glued
must not be colder than +5 °C or warmer than
+50 °C. Warm rapidly cooling materials (e.g.,
steel) for better adhesion.
GLUING
DANGER OF BURNING! The glue and the
nozzle tip (1) become very hot. Do not allow the
nozzle tip or hot glue to come into contact with
persons or animals. If hot glue touches the skin,
immediately hold the spot for some minutes under
a stream of cold water. Do not try to remove the
glue from the skin.
Models 910, 920 and 930:
Allow glue gun to reach operating
temperature before using (±5mins).
Insert the glue stick (2). Press the feed
trigger (3).
Model 940:
Once the cord is detached, the glue gun
remains operable for 5mins, before it
needs to heat up.
NOTE: For your first use, you may need to load
up to two full glue sticks before glue begins
to flow.