Télécharger Imprimer la page

Hülsta now! no. 15 21122 Notice De Montage page 22

Publicité

TYP 21122, 21121, 21127, 21128, 21129, 21112, 21111, 21117, 21118, 21119, 21222, 21221, 21227, 21228, 21229, 21212, 21211, 21217, 21218, 21219, 22122, 22121, 22127,
22128, 22129, 22112, 22111, 22117, 22118, 22119, 22222, 22221, 22227, 22228, 22229, 22212, 22211, 22217, 22218, 22219, 21322, 21321, 21327, 21328, 21329,
21312, 21311, 21317, 21318, 21319, 21422, 21421, 21427, 21428, 21429, 21412, 21411, 21417, 21418, 21419, 22322, 22321, 22327, 22328, 22329, 22312, 22311,
22317, 22318, 22319, 22422, 22421, 22427, 22428, 22429, 22412, 22411, 22417, 22418, 22419
MONTAGE · ASSEMBLY · MONTAGE · MONTAGE
Attention! The nature of the wall must be checked carefully by qualifi ed personnel before assembly. Assembly may then only be carried out by qualifi ed persons who carefully observe
these assembly instructions. The plastic TOX plugs PSD-SL 8 x 90mm from the fi ttings carton are only suitable, if the quality of the wall and the pressure resistance levels meet those
stated in the following table. The unit must not be assembled on light walls or masonry. In all other cases it is essential that a different and appropriate type of mounting is chosen
by a qualifi ed person. hülsta cannot be held responsible for the correct choice of a different method of mounting. During assembly please also make sure that there are no electrical
installations or other utility lines near the mounting area. This must be checked using an appropriate search device. Please note that plastic pipes will not be detected.
The mounting brackets included in the fi ttings carton are only suitable for the following types of wall. Please note that the pressure resistance levels must under no circumstances
fall below those stated.
Concrete
Concrete and solid
Solid brick
brickwork
Solid sand-lime brick
Vertical coring
brick
Perforated brick
with a dense
Concrete precision
structure
block
(Pressure
resistance
> 10.0 N/mm²)
Perforated sand-
lime brick
Solid brick
with a porous
Porous concrete
structure
SEITE 22
Depth of drilled hole
MONTAGEANLEITUNG
LOWBOARDS
LOWBOARDS
LOWBOARDS
LOWBOARDS
Carton of fi ttings for now! 15 140 / 210 cm lowboard for wall
12x
/16x
PSD-SL Ø 8x90
Pressure resistance
DIN 1045/1
>/= C20/25
>/= 20 N/mm²
ETAG 001
Pressure resistance
DIN 105
Mz 12
>/= 12 N/mm²
DIN EN 771-1
Pressure resistance
KS 12
DIN 106
>/= 12 N/mm²
KSL 12
DIN EN 771-2
Pressure resistance >
HIz 12
10 N/mm²
DIN 105-1
Pressure resistance >
10 N/mm²
Z-17.1-636
PNE
Pressure resistance >
ST 9
10 N/mm²
DIN 105-1
Pressure resistance
>/= 2,5 N/mm²
Anchoring depth
Screw length
Mat.-Nr.:1402724 / 1402725
12x
/16x
DIN 571 / 6x100
DIN 125 / 6.4
Recommended kind of drilling:
Hammer (Impact) drilling: Drilling with a hammer drill (high setting, better
drilling progress) for holes which need to be of a high quality. Suitable for solid
walls with a dense structure (concrete, etc). Holes must always be thoroughly
cleared of any drilling remains afterwards.
Percussion drilling: Drilling with a percussion drill (low setting) for brickwork
of a dense structure (solid bricks, solid sand-lime bricks). Holes must always
be thoroughly cleared of any drilling remains afterwards.
Rotary drilling: With a normal power drill, without percussion setting in per-
forated bricks (so that the connecting sections do not break and the hollow
section become too large). Holes must always be thoroughly cleared of any
drilling remains afterwards.
Rotary drilling: With a normal power drill, without percussion setting in porous
concrete. Holes must always be thoroughly cleared of any drilling remains
afterwards.
Depth of drilled hole
The hole itself must be deeper than the depth of anchoring. The extra space is
required to take the screw, which must always protrude beyond the tip
of the wall plug, especially in the case of plastic plugs.
12x
/16x

Publicité

loading