Maintenance; Fuel Filter; Spark Plug - Pinnacle Climate Technologies Remington SilentDrive REM-150T-SDR-B Manuel De L'utilisateur Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FUEL FILTER:

The fuel filter should be cleaned at least twice per heating
season. Clean the filter by rinsing it in clean K-1 Kerosene.
Contaminated fuel could make cleaning the fuel filter
necessary immediately.
NOTE: To remove the filter from models turn filter 90º
counter-clockwise. See Figure 6.
Fuel Line
Fuel Filter
Figure 6

SPARK PLUG:

Clean and re-gap every 600 hours of operation, or replace
as needed. After removing the spark plug, clean the
terminals with a wire brush. Re-gap the terminals to 0.140"
(3.5mm) See Figure 7.
Gap (3.5 mm)
Figure 7
© 2019 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR

Maintenance

Fuel Tank
Ignitor Wire
Spark Plug
Burner Head
WHILE CONNECTED TO A POWER SOURCE
PHOTOCELL:
The photocell should be cleaned using a cotton swab
dipped in alcohol or water at least once per heating
season, or more depending on conditions. See Figure 8.
Photocell Wire
Figure 8
NOZZLES:
Nozzles should be cleaned or replaced at least once
per heating season. Contaminated fuel could make this
necessary immediately. To clean dirt from nozzle, blow
compressed air through nozzle front. It may be necessary
to soak the nozzle in K-1 kerosene to loosen any dirt
particles. See Figure 9.
Nozzle Face
Nozzle
Dispenser
Silent Drive Forced Air Heater User's Manual
9
Photocell Photocell lens
X
X
Burner Head
Figure 9

Publicité