Operation - Pinnacle Climate Technologies Remington SilentDrive REM-150T-SDR-B Manuel De L'utilisateur Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Starting the Heater: (Ignition)
1. Fill the tank with kerosene or other approved fuel until
needle on fuel gauge points to "F".
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong (grounded) power
source. You must use a three prong (grounded)
extension cord that is at least 6 feet long and is a
minimum of 14 AWG rating.
4. Press the power button to power on the heater (see
Figure 3).
5. Select desired temperature using temperature +/-
buttons.
6. The heater will ignite once the temperature setting is
higher than the ambient temperature in the space.
Stopping / Restarting Heater:
To stop the heater, move the power switch to the
-
"Off" position and unplug the power cord.
To restart the heater; wait 10 seconds and follow
-
ignition steps.
Adjusting the Pump Pressure:
Remove the right side cover (4 screws). Behind the
-
panel, the pump will have a Phillips screw. There is a
small "P" next to the pump adjustment screw. Turn
screw in quarter turn increments.
Clockwise increases the pressure.
-
Counterclockwise decreases pressure.
-
© 2019 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
OPERATION (CONT.)
7
SDR 220 Rating Label + Control Panel
Model - Modèle
BTU/hr / kW
Fuel Consumption: Gal./Hr / L/h
Consommation de carburant: Gal./Hr / L/h
Fuel Tank Capacity: Gallon / Liter
Capacité du réservoir: Gallon / Litre
Pump Pressure PSI / BAR
Pression de la pompe PSI / BAR
TIP: If the heater does not ignite, the thermostat
V~Hz/Amps - V~Hz/Ampères
Fuse - Fusible
may be set too low. Increase the temperature to a
Phase - Phase
higher setting until the heater ignites.
Type of Fuel
Type de combustible
Maximum Air Outlet Temp. °C
Temp. maximale de sortie d'air °C
Minimum Distance From Combustibles:
Outlet: 8 ft. Sides / Top / Rear: 4 ft.
TIP: If the heater does not ignite; press power
Dégagement minimal des matériaux combustibles :
Sortie : 2,5 m
Côté / dessus / arrière: 1,2 m
button to power off the heater, check steps
See Operating Instructions and Troubleshooting
1-3 above and press power button to power
on side panel.
Voir les instructions de fonctionnement et de
ON the heater.
dépannage sur le panneau latéral.
COMPLIES WITH/CONFORME AUX
NORMES UL 733 AND/ET
CAN/CSA-B140.0-03 AND/ET CSA 140.8-1967
© 2018 Pinnacle Climate Technologies, Inc.
www.masterindustrialproducts.com
°F
Figure 3
Silent Drive Forced Air Heater User's Manual
MH-220T-SDR
220,000 / 64.5
1.67 / 6,3
13 / 49
123 / 8,48
120V~60Hz / 3.15
3.15A
No. 1 / Kerosene
n ° 1 / Kérosène
552
Made In China
Fabriqué en Chine
°F
MASD-003

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Remington silentdrive rem-220t-sdr-b