A
Shore supply. AC in: (left to right) PE (ground), N (neutral), L (phase).
B
Connector for remote panel.
C Load connection. AC out: (left to right) PE (ground), N (neutral), L (phase).
D Megafuse F4.
E
Battery minus.
F
Battery plus.
G Terminals for: (left to right) Voltage sense plus, Voltage sense minus, Starter battery plus,
Starter battery minus, Temperature sensor plus, Temperature sensor minus.
H Connections for remote switch: Short left and middle terminal to switch the Multi "on", Short
right and middle terminal to switch the Multi to "charger only".
I
Dipswitches DS1 tm DS8 for set-up mode.
J
Pushbuttons for set-up mode.
K
Used for Parallel and 3-Phase operation, J7 IN.
L
Used for Parallel and 3-Phase operation, J8 OUT.
M "Reversed polarity" LED.
2