- Consider environmental influences. Do not expose
the device to rain and avoid working near
combustible liquids or gases.
- Store the device in a dry, locked place outside the
reach of children.
- Regular cleaning of the device is an important
safety factor. Pull the plug before starting this
work.
- The device must be set up on level ground such
that it can neither tilt over nor roll away (lock
steering rollers).
- The cleaned air may only be recirculated to those
workspaces from where it was extracted; i.e. the
electronic tool and the dust extractor may only be
operated in the same workspace.
- In case of leaking foam or water, immediately
switch off the device. Empty container and where
necessary folded filter.
- Acid, acetone and solvents may corrode device
components.
- Do not leave the device unattended. Pull the power
plug in case of longer work interruptions.
- If the device's connecting cable is damaged, it
must be replaced by a special connecting cable
that is available from the manufacturer or his after-
sales service.
- Have repairs only carried out by skilled workers,
e.g. by the after-sales service. If not professionally
repaired, devices will constitute a danger for the
user.
- Only
use
original
accessories or special accessories. Otherwise, the
manufacturer will not accept any warranty claims
and cannot be held liable.
MAFELL
spare
parts,
4

Setting / Adjustment

4.1 Assembly

Pay attention that the container's two snap locks
have safely engaged in the recesses on the
motor hood.
Push the suction hose fitting over the
container's suction opening and turn it until the
hose fitting engages.

4.2 Mains connection

The dust extractor S 35 HEPA is equipped with
protective earthing acc. to class I and may therefore
only be connected to sockets with protective earth
conductor.
Prior to commissioning make sure that the mains
voltage agrees with the operating voltage stated on
the machine's rating plate.

4.3 Changing the folded filter cartridge

Shake off the folded filter cartridges before
changing the filter.
Using a coin or similar object, turn the catch 7
(fig. 1) on locking bolt 9 anticlockwise by 90°
and push the locking bolt 9 to the rear.
Swing open the hood and remove the filter
cartridge 5 (fig. 5) towards the top.
Immediately seal the removed folded filter
cartridges in a dust-tight plastic bag and dispose
of in accordance with the instructions.
Insert the new filter cartridges and pay attention
to a neat and tight fit of the filters.
Fold down the hood and return to its initial
position by slightly pressing on the locking bolt 9
(fig. 1). The device is now once more closed.