Recording measured values
Recording measured values with default PROJECT settings
In this setting, measurements are made using a defined sensor configu-
ration. This configuration is defined by the user using the PC software.
This avoids false measurements and wrong settings.
The preset parameters are altered in the PC software and transferred to
the measuring instrument.
The following parameters can be set:
Menu
Setting/
pre-selection
REC
No:
NAME>
1 . . 5
INPUT>
PILOT PRS
WRONG
USE
SENSOR !
CORRECT
FS
SENSOR!
When all of the sensors are connected, the respective type of record-
ing (START/STOP, POINT, AUTO TRIGGER, MANUAL) is selected and
performed automatically.
116
Notes
Load Test
There are max. 5 prede-
fined settings (tests) avail-
able for selection.
Defined sensors are de-
fined for each channel.
150 bar
Warns of wrong sensor.
A pressures sensor with
the corresponding FS (full
scale) must be connected
to this channel.
600 L/min
Indicates correct sensor.
The next channel can be
connected.