4
SETTINGS
FACTORY VALUE
X
ORANGE
GREEN
OFF
5
CALIBRATION
RED-GREEN
OFF
GREEN
RED
4
ORANGE
5
6
DOOR SAFETY CHECK
IMPORTANT: Test the good
functioning of the installation
before leaving the premises.
If necessary, position spots
closer to or away from the door
and relaunch a calibration.
MOUNTING
SIDE
RELAY 1
ON
OPENING SIDE
RELAY 2
OFF
CLOSING SIDE
LED during detection:
R1 > RED
R2 > GREEN
When the LED is off on all modules, the detection zone is OK.
The detection zone is too short:
turn the screw clockwise.
The detection zone is too long:
turn the screw anticlockwise.
Step out of the detection field.
If necessary, change angle or switch off background (DIP 3 = OFF).
Launch a new calibration.
FREQUENCY
BACKGROUND
FREQ A
FREQ B
Set different
Not enough background
reflectivity: switch to OFF
frequencies on
modules close to
each other.
* Recommended for most applications.
Mounting height > 2.7 m: set to LOW for
EN 16005 and DIN 18650-conformity.
After changing a DIP-switch, the orange LED flashes.
A LONG push on the push button of the MASTER
confirms the settings of ALL MODULES.
Afterwards, a number of green flashes (x) indicates
the number of connected modules.
A SHORT push on the button of the MASTER launches a
calibration on ALL MODULES.
Do not stand in the detection field!
UNCOVERED
ZONE
ON
HIGH*
OFF
LOW
Approximate values at 2 m:
high= 40 cm, low = 15 cm
The flashing speed of
the LED increases when
approaching the optimal
position.
GC 334