TOPPING UP ThE OIL-DYNAMIC CIRCUIT
Verify periodically (15000 cycles), that the oil level does not go below 3/4 of the limit indicated by the proper indicator (I). Whether you need to top the
circuit up, remove the plug (h) using a 19 mm wrench, then let in the oil hLP 32 cSt until reaching the lip of the threaded hole.
ATTENTION!If you fail to perform this operation, you will note power loss that will lead to compromise the proper working. Therefore, it will be necessary
to get rid of the air from the hydro-pneumatic circuit and restore the exact oil level.
Then proceed as follows: position the Booster higher than the handle and the supply pipes as shown in picture, remove the cap (h) by a 19 mm wrench.
Top up with oil, perform a few riveting cycles adding oil while keeping the handle down with respect to the Booster, as per picture. Repeat the operation
until the optimal stroke is reached.
Topping up is completed when the oil level is stable and touches the lip of the threaded hole. Fit again the cap (h).
It is very important to follow the above mentioned instructions and always use gloves when you handle the machine. The overflow oil must be collected
in proper containers and delivered afterwards to authorised waste companies.
DO NOT SMASH OR CUT THE CONNECTING PIPES BETWEEN GUN AND BOOSTER.
mm 19
I

DEVICE DISPOSAL

For the device disposal, comply with the national laws. After disconnecting the device from energy sources, start the
disassembly of the components according to their material: steel, aluminium, plastic and so on.
Go on with the scrapping in accordance with the nationl standards.
ATTENTION !!!
WE RECOMMEND TO USE OIL HLP 32 CST OR SIMILARS.
H
75036031 - FHU5000 – rev 03 - ( 12-2021 )