Programming Overview
3-9
Menu-
No.
Entry
Selection
point
1
Motor pump overcurrent
0
0,0 A
1
2,6 A
2
3,2 A
3
3,8 A
4
4,4 A
5
5,0 A
10
6
5,6 A
7*
6,2 A
8
6,8 A
9
7,4 A
10
8,0 A
11
8,6 A
12
9,2 A
Automatic time
0
3 s
1
5 s
2
7 s
3
9 s
13
4
11 s
5*
13 s
6
15 s
7
20 s
8
25 s
9
30 s
Automatic return
0*
aus
1
0,2 s
2
0,4 s
3
0,6 s
4
0,8 s
14
5
1,0 s
6
1,2 s
7
1,4 s
8
1,6 s
9
1,8 s
10
2,0 s
Wheel chock
15
0*
0*
without wheel chock
with wheel chock
1
1
Operating options
0
Door – dock leveller mutual interlocking
1
Without door – dock leveller interlocking
17
Door
– dock leveller interlocking
2
3
Dock leveller interlocking when door is not open
4*
Only dock leveller operation
5
Only door operation
- -
- -
Exit menu
Shelter
2
20
0*
off
1
inflatable Shelter
Delay time door closed
21
0 - 12
0*; 5s;10s;15s;20s;25s;30s;35s;40s;45s;50s,55s;60s
22
Delay time door opens
- -
0 - 12
0*; 5s;10s;15s;20s;25s;30s;35s;40s;45s;50s,55s;60s
- -
Exit menu
Menu
Item
30-
without sensor
Enter
1x
Menu-
No.
Entry
Selection
point
3
Setting the door's top end-of-travel position
30
Change of direction (press for 5 sec.)
31
Setting the door's bottom end-of-travel position
50*
Fine adjustment of top end-of-travel position
33
50 - 0
0... 80mm deeper
50 - 99
0... 80mm higher
50*
Fine adjustment of bottom end-of-travel position
34
50 - 0
0... 80mm deeper
50 - 99
0... 80mm higher
Selecting the closing edge
Measuring value display (press for 5 sec.)
0
Optical closing edge OSE
35
1*
Electrical safety edge 8K2
2
Pressure wave edge DW with testing
Electrical safety edge 8K2 with slack rope switch
3
Selecting the photocell
0*
without photocell
1
2-wire photocell Ls2
2
4-wire photocell Ls5, Reflection photocell
36
3
Photocell LS2, frame fitted
4
Photocell LS5, frame fitted reflection photocell
5
2-Drahtlichtschranke Ls2, with stop during Open
6
4-Drahtlichtschranke LS5, with stop during Open
25*
Adjustment pre-limit switch safety edge
37
25 - 0
0... 50mm deeper
25 - 99
0... 100mm higher
- -
Exit menu
Selecting the operating modes
4
0
Dead man OPEN / Dead man CLOSE
40
1
Impulse OPEN / Dead man COSE
2*
Impulse OPEN / Impulse CLOSE
Response of safety edge
41
0*
Full reversing
1
Partial reversing
Correcting the slowing-down path
42
0
off
1*
on
Level adjustment
0*
off
1
Advance end stop by closing edge
43
2
activated for 200 cycles
3
activated for 1000 cycles
4
active without limitation
GB
Exit
* Factory settings