Technical data
Digital Detector
Article number
A)
Max. detection depth
– Ferrous metals
– Non-ferrous metals (copper)
– Live wires 110−230 V (with voltage applied)
– Wood
Operating temperature
Storage temperature
Inductive sensor
– Operating frequency range
– Max. magnetic field strength (at 10 m)
Capacitive sensor
– Operating frequency range
– Max. electric field strength (at 10 m)
Max. altitude
Relative air humidity max.
Pollution degree according to IEC 61010-1
Battery
Approx. operating time
Weight according to EPTA-Procedure 01:2014
Protection rating
A) Depends on operating mode, material and size of the objects, as well as material and condition
of the base material
B) Lower detection depth with non-live wires
C) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by
condensation is expected.
The serial number (14) on the type plate is used to clearly identify your measuring tool.
The accuracy and detection depth of the measuring result may be negatively af-
u
fected if the condition of the substrate is unfavorable.
Bosch Power Tools
B)
–10 °C to +50 °C
–20 °C to +70 °C
IP 54 (dust and splash-proof)
1 609 92A 5DB | (23.02.2021)
English | 21
GMS 120
3 601 K81 0..
120 mm
80 mm
50 mm
38 mm
5 ± 0.2 kHz
72 dBµA/m
20 ± 1 kHz
24 dBµV/m
2000 m
90 %
C)
2
1 × 9 V 6LR61
5 h
0.27 kg