Page 8
ENGLISH
Section 2. General Description
2.1
Introduction
This manual contains information for the proper
installation, operation, and maintenance of Jandy FloPro
Series VS-FHP variable speed pumps. Procedures in this
manual must be followed exactly. To obtain additional
copies of this manual, contact Zodiac
Service at 800.822.7933. For address information, see
the back cover of this manual.
2.2
Description
The VS-FHP is a variable-speed pump that can be
run from 600 RPM to 3450 RPM. When connected to
the JEP-R controller, up to eight (8) speed settings may
be programmed and recalled. This allows you to select
the most appropriate speed for your application. Even
more versatile programming is possible when you use
an AquaLink
RS or AquaLink PDA controller.
®
The pump is driven by a variable speed PMSM
(Permanent Magnet Synchronous Motor) directly
attached to the pump impeller. The motor spins the
impeller which forces water to flow through the pump.
As the speed of the motor is varied the flow through
the pump is also varied. The adjustable flow rate allows
for optimization of flow during the varying pump cycle
requirements. As a result the energy efficiency of the
pump is maximized resulting in cost savings to the pool
owner while also helping to save the environment.
Figure 2.
Typical Piping Installation
Jandy
®
FloPro™ Variable-Speed Pump Series VS-FHP
Customer
®
|
Section 3. Installation Information
3.1
Plumbing
3.1.1 Preparation Information
1.
Upon receipt of the pump, check the carton for
damage. Open the carton and check the pump for
concealed damage, such as cracks, dents or a bent
base. If damage is found, contact the shipper or
distributor where the pump was purchased.
2.
Inspect the contents of the carton and verify
that all parts are included. See Section 7.1,
Replacement Parts List and Exploded View.
3.1.2 Pump Location
1.
Zodiac Pool Systems, Inc. recommends installing
the pump within one (1) foot (30 cm) above water
level. The pump should not be elevated more than
a few feet above the water level of the pool.
NOTE To achieve better self-priming, install the
pump as close as possible to the water level
of the pool.
2.
If the pump is located below water level, isolation
valves must be installed on both the suction and
return lines to prevent back flow of pool water
during any routine or required servicing.
NOTE When the pool equipment is located below the
pool surface a leak can result in large scale
water loss or flooding. Zodiac Pool Systems,
Inc., cannot be responsible for such water
loss or flooding or damage caused by either
occurrence.
AQUAPURE
Installation and Operation Manual
MANUAL BY-PASS DETAIL
MANUAL BY-PASS IS USED
WHEN FILTRATION RATE
EXCEEDS 125 GPM