TROUBLESHOOTING AND SOLUTIONS
If the unit does not work properly, perform the following checks before contacting the Technical Support Service:
PROBLEM
Slack power supply connections.
The unit does not
No power supply voltage
switch on.
Intervention of the circuit breaker
and/or differential switch of the
power supply line.
The cycle does not
Door open
start
The display is showing the alarm
Er 3 or Er 4
The cycle stops and
The display is showing the alarm
the machine switches
Er 7
to blocked status.
The display is showing the alarm
Er 0
Excessive quantity of material in
the washer.
Excessive humidity on
the materials at the
Materials not properly placed.
end of the cycle.
Obstructed filters.
I
F THE PROBLEM PERSISTS
MODEL AMD SERIAL NUMBER
T
HESE INFO ARE REPORTED ON THE DATA PLATE ON THE UNIT REAR AND ON THE WARRANTY CERTIFICATE
POSSIBLE CAUSE
NOTE
,
T
CALL THE
ECHNICAL SUPPORT SERVICE
.
SUGGESTED SOLUTION
Check the terminals on the switchboard and restore the
connections.
Check the cause of the power failure.
Reset the switches and try again the operation.
Close tight the door.
Door open . Close tight the door and repeat the cycle.
No water. Check that the water tap is open. Repeat the
cycle.
Black-out during the cycle. Repeat the cycle.
Check the quantity of material and does not exceed the
max value allowed
(See Appendix A, "Technical characteristics").
Positions the materials according to indications.
(See Chapter "Load of materials").
Call the Technical support service
(See Appendix Z, "Technical support").
(
A
SEE
PPENDIX
Z)
COMMUNICATING
.