LOCATION OF THE COMPONENTS OF THE COLLECTION TANK UNIT

The components of the collection tank are as follows:
1. Collection tank.
2. Front pivoting wheels.
3. Rear wheels.
4. Vacuum motor control switch.
5. Exhaust air noise reduction filter.
6. Control handlebar.
7. Collection tank lid coupling - uncoupling hinges.
The stages for making the appliance safe, thereby making it possible
to carry out operations safely, are as follows:
1. Make sure that the main switch (1) is in the rest position, if not,
disable it by pushing the switch to "0" (Fig.1).
2. Make sure that the plug (2) on the power cable (3) has been
taken out of the mains supply socket (4), and if not, disconnect
it (Fig.2).
3. Wind the cable around the control handlebar.
OFF
OFF
1
Before beginning to work, it is necessary to:
1. Before using, the appliance must be in order and safe to use
with the work equipment, especially the power cable and the
extension cable. If everything is not in order, the appliance must
not be used.
2. Take all necessary steps to ensure that the device is in a safe
condition (see
MACHINE
SAFETY'").
ATTENTION: Users are advised to always wear protective
gloves, to avoid the risk of serious injury to hands.
1
1
9. Fix the cover to the collection tank by using its hooks (1) on the
side of the collection tank ( Fig. 6).
ATTENTION: The collection bag-filter should only be used for
collecting solid waste.
ATTENTION: When using the collection bag, do not vacuum
waste that could cut it, burning embers that could set it
on fire, or acid solutions that could dissolve it.
10. Make sure that the cap closing the vacuum nozzle (5) has been
correctly inserted (Fig.7).

APPLIANCE SAFETY

4
1
2
3
2

PREPARING TO WORK

2
2
22
1
2
1
ATTENTION: Users are advised to always wear protective
gloves, to avoid the risk of serious injury to hands.
ATTENTION: To prevent any damage to the mains socket,
pull out the plug (2) from the mains socket (4) by pulling
the plug (2) directly instead of the power cable (3).
3. Free the cover from the collection tank by releasing its hooks (1)
on the side of the collection tank ( Fig. 1).
4. Remove the cover (2) from the collection tank (Fig.2).
5. Put the cover delicately on the floor.
6. Check that the fabric vacuum filter (3) is inside the tank, if not
put it in (Fig.3).
7. Insert the collection bag (4) inside the collection tank (Fig.4),
being careful to position it correctly inside the filter.
ATTENTION: To fix the collection bag fold the hem around the
inlet mouth of the collection tank.
8. Put the cover (2) on the collection tank (Fig.5).
3
3
11. Insert the vacuum hose (6) into the vacuum nozzle (7) in the
cover (Fig.7).
12. Select the most suitable accessory for the work to be carried out.
13. Insert the selected accessory into the vacuum hose.
ATTENTION: Never use the appliance without the filters
supplied with the machine.