CONFIGURATING BASIC PARAMETERS
The VORT T control box allows to control the ventilation based on the wind speed
(Mode A) or the temperature (Mode B), by using specific probes. Generally the
controller is equipped with a temperature probe and then adjusted to an operation
in B mode, relying on the temperature present in the environment.
It is possible change mode every moment, following these steps:
•
Shut the VORT T power system down and then turn it on;
•
Once turned it on, keep pushed SET button till 4 lines appear on the di
splay;
•
Stop pushing the SET button.
To visualize in which mode you are operating, it is sufficient shut the control box down and then
turn it on again.
The parameters control can be made in two ways: automatic or manual.
The first one is suggested for the final user, because the control box sets up the fan functions in au
tomatic and based on the data acquired, the fan speed is increased or decreased. This is the de
fault mode.
The manual mode allows to take control manually and modify , for example, the number of RPM of
the fan, independently of the microclimatic conditions. This mode is suggested
only during the initial test or in maintenance conditions, in order to check out if
everything is working properly. To enter in this mode, push both ACTION but
tons for 5 sec. and then click on ACTION to change the fan speed.
Press the ACTION keys simultaneously for approximately 5 sec. to exit.
Briefly, the ventilation control can be made by using:
•
Wind Speed (Mod. A);
•
Temperature (Mod. B).
The ventilation needs to be set up and configured with costant data.
Attention: not all parameters must be changed, because many of them are default ones.
SETTINGS
Mode B – Dominant parameter Temperature
Settings concern setting up the temperature in which fans start to move. To do this push the
SET button and click on INCR/DECR to regulate the temperature.
Clicking again SET, it is possible to insert also the wind speed in which the machine stops. (only
if the control box is equipped also with the anemometer). Press ACTIONCLOSE to exit.