4.3
Mounting the product
CAUTION
FloCo-Top-1K
The permissible ambient temperature must not be exceeded,
see table 1, page 4. This means that you must not mount the
FloCo-Top-1K on top of or next to a non-insulated boiler part,
above opening dampers at furnaces or to the flue gas pipe.
The float housing must point vertically to the top.
1.
Mount FloCo-Top-1K to the boiler casing using the enclosed
bracket 4 self-tapping screws.
You can use the bracket as a template when screwing in the
screws (points upwards).
2.
Mount the suction line into the female thread G 3/8 of the hous-
ing with a cylindrical screwed pipe connection G 3/8 as per
DIN 3852 (see chapter 8, page 14) or with the enclosed cop-
per flat gasket and seal it.
Do not use hemp or Teflon tape.
3.
Use a support bushing in the case of soft or semi-soft copper
pipes.
4.
Lock with an open ended spanner size SW 24 and tighten the
screwed connection at the housing.
5.
Mount the burner hoses.
Make sure the sealing surfaces are clean and not damaged.
Damage to the pump or tor FloCo-Top-1K if the flow and return
lines are not properly connected
Do not confuse the supply and return connections, not even
during commissioning for a short period of time.