Mounting Guidelines
The IRPI800M is designed for use indoors. The sensor can be
corner, wall or bracket-mounted (see the Accessories section).
Ensure that the sensor has a clear line of sight to the protected
area; infrared light cannot penetrate solid objects, and the sensor
must «see» an area in order to detect a moving person.
The sensor should be pointed into the interior of the room, and
be placed away from windows and heating/cooling sources.
Additionally, the sensor should be fixed to a surface where the
temperature is similar to that of the area being protected, and not
pointed at direct or reflected sunlight.
Special Instructions for Installing with Pets
To take full advantage of the pet immunity in the IRPI800M,
follow the guidelines below:
•
Mount the sensor with the centre of the lens at exactly
2.30 m high.
•
Set the sensor to the Low or Lowest sensitivity setting as r
required by the application (see Step 6).
•
At the Lowest sensitivity setting, the total combined
weight of animals may not exceed 36 kg (80 lb).
•
At the Low sensitivity setting, the total combined weight of
animals may not exceed 18 kg (40 lb).
•
The look-down mask (P/N 5-532-719) must be installed
(pre-installed).
•
The Pet Immune lens must be installed (P/N 5-532-719,
pre-installed).
•
Mount the sensor where pets cannot come within 1.80 m
(6 feet) of the sensor by climbing on furniture, boxes or
other objects.
•
Do not aim the sensor at stairways or furniture/objects that
can be climbed on by animals.
•
Environmental differences and the amount of heat readiated
by an animal will vary the animal immunity levels exhibited
by the sensor.
Each installation should be tested to determine the exact level
of animal immunity attainable.
Tamper Switches
The IRPI800M is equipped with a normally-closed cover tamper.
This tamper opens when the cover is opened.
A wall tamper switch is also provided. To use the wall tamper
switch, remove the PCB and the Tamper Knockout located
toward the bottom of the back cover (see Step 2).
Before mounting the sensor, install a tamper screw in the wall so
that it protrudes approximately 6 mm (1/4") above the mounting
surface. Replace the PCB and mount the sensor on the wall, over
the tamper screw. The screw will depress the back tamper lever as
shown.
LED Operation
To Enable the alarm LED, turn switch S3 to OFF.
To Disable the alarm LED, turn switch S3 to ON. The LED will
temporarily remain enabled for 10 to 12 minutes. This feature
gives the installer time to walk-test the unit as explained below.
LED
LED enabled
To restart the 10-minute walk-test, activate the tamper switch by
opening and closing the cover.
OPERATION
LED
Enabled
Conditions
Disabled
Warm-Up
Slow Blink
Slow Blink
~2.5 mins
(
)
Short illumination
*See above
Detection
Long illumination
*See above
Alarm
NB. If registered on Galaxy or Vista, the LED blinks twice upon
alarm.
Walk-Test Mode
After applying the power to the sensor, it will warm up for up
to 2.5 minutes. After this, when the cover is closed (operation
of the tamper switch) the product enters into walk-test mode
for 10 minutes. The LED remains active whatever the
position of the switch and each detection results in an alarm
signal being sent. To restart the 10 minute test period, operate
the tamper switch by opening and closing the cover.
Battery Fault
The sensor signals a battery failure at the control panel when
the battery needs to be replaced. The sensor will continue to
operate for up to one week after this.
Masking the Lens
If the installation requires the blocking of certain segments, it is
possible to mask part of the lens with the masking material
provided. If you require only look-down beams, you can mask the
entire lens.
To mask segments of the lens:
•
Open the sensor housing and take out the lens (see Step 4).
•
Select the appropriate segments to be masked, and place the
mask over the inside of the lens.
•
Use Lens Mask K9854 to mask the Long, Intermediate and
Lower Range on the Pet Immune lens (P/N 5-532-719,
pre-installed).
•
Use Lens Mask K9855 to mask the Long, Intermediate and
Lower Range on the High Security lens (P/N 5-532-477,
supplied).
Detection Patterns
View from Above
Wide Angle Pet Immune (pre-installed) and Wide Angle High
Security (supplied).
Note : The distances in the illustrations do not represent the
maximum detection distances. A walk-test is required after
mounting to ensure proper detection.
Side View
Pet Immune lens (pre-installed)
High Security lens (supplied)
* Look-down beams are fully enabled only when the look-
down mask is removed (see Step 5).
Note: Enabling the look-down beams is not recommended
in pet immune installations.
Specifications
Range:
immunity.
11 m x 12 m
22 long range, 12 intermediate
Pet/Animal Immunity:
6 lower, 4 look-down
36kg, 18kg, 0 kg
Dimensions:
Installation Height (centre of lens):
11.2 cm x 6.0 cm x 4.0 cm
2.30 m to 2.70 m [2.30 m is the
Weight: 84g
ideal installation height]
Packaged Product:131g
Power Requirements:
Accessories Included:
1 lithium 3v battery, type CR123A
1 battery
1 Pet Immune Lens [pre-installed]
(supplied)
P/N 5-532-719
Current:
High Security Lens (P/N 5-532-477)
Quiescent current: 25µA max
Mask for Pet Immune Lens
Operational current: 45mA max
(P/N K9854)
Battery Life, Panels:
Mask for High Security Lens
Galaxy and Vista: 3 years, min.
(P/N K9855)
Domonial: 4½ years, min.
Look-down mask.
Tamper Switches:
Front cover fixing screw.
Cover: Opening
Accessories Available:
SMB-10 Swivel Mount Bracket
Wall: Wrenching off wall.
(P/N 0-000-110-01).
White Light Immunity:
SMB-10C Swivel Mount Ceiling
6,500 Lux (min.)
Bracket (P/N 0-000-111-01)
Sensitivity:
(see note 3)
Selectable (Lowest, Low, Medium
and High)
Certifications:
Temperature:
- EN 50131-1 et TS 50131-2-2
o
o
Operational: -10
to 55
C
Grade 2; Environment Class II.
Storage: -20
o
to 70
o
C
Certified NF&A2P according to
Relative Humidity:
C48433 Type 2
5% à 95% Without condensation
Certifying authorities: CNPP Cert &
Temperature Compensation:
CNMIS. Cert. No: xxxxxxxxx.
Dual Slope
Radio:
Note 1: The High Security.Non-Pet
Immune lens and Swivel Mounting
Type: FM narrow band
Brackets should not be used in pet
Frequency: 868Mhz
applications.
Range: 2000m unobstructed
Protocol: Alpha (Domonial), V2 GY
Note 2: In TS 50131-2-2 compliant
(Galaxy and Vista)
installations, mount the sensor at
Supervision:
2.30 m, use the High Security lens,
18 min (Alpha), 9 min (V2 GY)
select the high sensitivity setting and
PIR Detection Field:
use the cover screw (supplied).
Pyroelectric dual element
- Pet Immune Lens
Note 3: The use of accessories (swivel
mounts) is not covered by NF&A2P
44 long range, 36 intermediate
18 lower, 4 look-down
certification or by conformity to
technical specification: TS50131-2-2.
- High Security lens without pet