DSC100
WARNINGS FOR THE USER
In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service.
Periodically check functioning of the safety devices. Any repairs must be carried out by specialised personnel using
original and certified materials. The appliance is not to be used by children or people with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
Do not access the control board for settings and / or maintenance.
WARNING: IMPORTANT SAFETY INSTRUCTIONS
It is very important to follow the present instructions for your own safety.
Please keep this manual
ELECTROMAGNET INSTALLATION - FIG. 2
1. Remove the unlocking body after having unscrewed the 2 Allen screws. The same holes M6 are used to fix the
electromagnet.
2. Fix the support flange (1) to the gearmotor body by means of the countersunk head screw (A).
3. Drill the gearmotor body (Ø = 6) in correspondence to the hole inside the slotted hole (2) and run the electromagnet
cables through the gearmotor body.
4. Fix the electromagnet (3) to the flange with the cylyindrical head screw L = 16 mm (B) and to the gearmotor body by
means of the cylindrical head screw L = 30 mm (C)
ELECTRICAL CONNECTIONS: TERMINAL BLOCKS
Terminal
Position
1
J9
2
3
J5
4
5
J8
6
7
J3
8
9
10
J2
11
12
PROTECTION FUSES
Position
Value
F1
1 A
Signal
Description
L
Power input 230 Vac
N
Power input 230 Vac
COM_FC
Common limit switch
Limit switch input
FC
COM_STOP
Common emergency STOP push button
STOP
Emergency STOP push button input
NC_EM
NC contact for electromagnet connection
NO_EM
NO contact for electromagnet connection
COM_EM
Common contact for electromagnet connection
L/S
Common flashing light
S12/24
Flashing light input 12/24 Vdc
L12/24
L230
Flashing light input 230 Vac
Type
Description
FAST
Electronic board protection
See NOTE 1
9
UK