TEC29, TEC29LPG
You can secure the generator with the holders supplied in two ways:
External installation (fig. 2, page 3):
External installation has the following benefits: lower space requirement,
fast installation, easy access for maintenance work.
– To ensure the generator is attached securely, use the retaining
bracket (fig. 2 1, page 3) supplied.
– If the air intake opening of the generator is located behind a vehicle
wheel, you need to prevent the wheel from splashing any water into
the generator interior when it rains (e.g. by using a splash guard).
Internal installation (fig. 3, page 4):
For internal installation, you need to prepare a sealed compartment
against the vehicle interior which can also be insulated against sound.
– Attach exhaust and air intake openings to the floor and in front of the
generator cover. The air intake openings must have cross-section of
at least 240 cm
– You must also fit a seal (AG 128; available as an accessory) made of
fire-retardant rubber with a thickness of at least 5 mm between the
floor of the vehicle and the generator.
Leave a space of at least 20 mm between the generator hood and sur-
rounding parts so that sufficient space remains for cooling air to pass
through.
9.3
Securing the silencer
Observe the following instructions when installing the exhaust pipe:
Do not create any sharp bends which will inhibit the flow of exhaust
fumes.
Align the manifold (fig. 4 1, page 4) along the housing to ensure greater
damping of vibration.
Use the exhaust pipe extension to extent the exhaust pipe (fig. 4 2,
page 4) (see chapter "Accessories" on page 18).
Secure the extension to the vehicle floor (fig. 4 3, page 4).
➤ Secure the silencer (fig. 4 4, page 4) as in one of the alternatives shown
in fig. 5, page 4 to fig. 9, page 6.
EN
2
.
Installation
21