FVE trench heater basic wiring diagrams
Základní schéma zapojení pro konvektory FVE
Heating
L
N PE
N
230 VAC
L
24 VDC
35 W
SIEMENS RDG 160T or RAB21-DC thermostat controlled trench heater wiring diagrams
Schéma zapojení pro konvektory FVE řízené termostatem SIEMENS RDG 160T nebo SIEMENS RAB21-DC
Heating
SIEMENS THERMOSTAT RDG 160T
L
N PE
N
230 VAC
L
24 VDC
35 W
Setting the parameters of the SIEMENS RDG 160T thermostat
Parameter
P01
P02 P03
Setting
0
2
2
ON
DIP
1 2 3 4 5
Further wiring diagrams can be found at www.licon.cz, or upon request. The RDG 160T thermostat is pre-set for 2-pipe heating systems. For alternative
methods of heating, the SIEMANS RDG 160T or RAB21-DC thermostats must be set according to the instructions enclosed, or see downloads at
www.licon.cz.
V+
V-
SIEMENS TEMPERATURE SENSOR QAAH32
B1
X
V+
V-
P30
P32
P38
P40
P42
P46
P47
0.5
0.5
0
0
0
1
1
FCR BOX
SNGD
Valve
+Upwr
+
Ucntrl
VALVE
C
-
0Vpwr
+
VALVE
H
-
SIEMENS THERMOSTAT RAB21-DC
FCR BOX
SNGD
Valve
+Upwr
+
Ucntrl
VALVE
C
-
0Vpwr
+
VALVE
H
-
P53
P55
P56
P57
P59
P72
3
96%
40%
10%
1 min
2
0-10 VDC
GND
VENTIL 24 VDC
L
N
230 VAC
PE
HEATING VALVE
24 VDC
0-10 VDC
L
N
230 VAC
PE
HEATING VALVE
24 VDC
Další schémata zapojení nalez
Termostat RDG 160T je již pře
V případě požadavku na jiný z
160T a RAB21-DC nastavit dle
nebo je k dispozici v sekci ke s
EN