TABLE 4. TROUBLESHOOTING CHART
Below­in­chart­form­are­various­symptoms­of­a­malfunctioning­
system, possible defects that will cause there symptoms and
suggested­corrective­measure.­The­chart­assumes­that­the­proper­
SYMPTOMS
Burner­light­off­very­slow­
Burner­light­off­very­slowly­
Color stays dull
Burner­flashback­
(roaring­noise­during­operation­­
and­ceramic­grid­surface­will­be­dark)­
Ceramic grid or burner sooting up
(when­new­or­after­cleaning)­
­
­
Pilot­cannot­be­ignited­
­
­
­
Pilot­lights­but­goes­out­
­
Pilot­stays­lit­but­main­burner­will­not­light­
­
­
Failure­to­ignite­
­
­

HIGH ALTITUDE OPERATION

1.­ Please­contact­the­factory­for­a­detailed­High­Altitude­
Conversion­Kit­to­suit­your­specific­need.
1.1­Be­prepared­to­answer­factory­questions­
regarding:­Type­of­fuel­for­the­proposed­appliance­
conversion,­gas­pressure­available­at­site,­and­specific­
altitude at site.
2.­ "The­conversion­shall­be­carried­out­by­a­
manufacturer's­authorized­representative,­
in­accordance­with­the­requirements­of­the­
manufacturer,­provincial­or­territorial­authorities­
having­jurisdiction­and­in­accordance­with­their­
requirements."
3.­ High­Altitude­Conversion­Kits­will­include­high­
altitude rating plate with stamped data, necessary
orifices­or­burner­as­required­for­specific­need­and­
additional installation instructions.
4.­ In­Canada,­Heater­installations­at­High­Altitudes­shall­
comply­with­the­applicable­construction­provisions­of­
the­current­standard­CAN1-2.17,­gas­fired­appliances­
for use at high altitudes.
Enerco Group, Inc. | Gas-Fired Infra-Red Space Heaters
gas­pressure­is­available­to­the­heater­and­that­the­lighting­
procedure is as stated on the plate attached to the heater.
CAUSES
Partially­blocked­pilot­orifice­
Pilot out of adjustment
Partially­blocked­burner­orifice­
Low­gas­pressure­
­
Damaged­burner­
First­check­for­damaged­­
burner orifice
If­burner­orifice­is­not­damaged­
then­check­for­damaged­manifold.­
Blocked­pilot­orifice­
Gas­cock­not­in­position­
Pilot­gas­flow­adjustment­screw­may­be­closed­ ­ G as­control­knob­must­be­turned­to­pilot
­
Defective­thermocouple­
Defective­control­
Loose­wire­or­improperly­wired­
Defective­control­
Blocked­burner­orifice­
Main­gas­off­
Air­in­gas­line­
Loose­wire­connections­
Dirty wire connections
E7
Operating Instructions and Owner's Manual
SOLUTIONS
Re-adjust­pilot
Replace
Replace
Correct­line­pressure­or­call­your­gas
supplier
Replace
Replace­if­damaged
Replace
Replace­
­
­
and held depressed
Open­and­adjust­(see­Figure­8)
Replace
Replace
Tighten­connections,­check­wiring
diagram
Replace­
Clean orifice or replace
Open­manual­valves
Bleed­gas­line
Tighten­wire­connections
Clean terminals and secure terminals
­
­