TABLE 4. TROUBLESHOOTING CHART
Belowinchartformarevarioussymptomsofamalfunctioning
system, possible defects that will cause there symptoms and
suggestedcorrectivemeasure.Thechartassumesthattheproper
SYMPTOMS
Burnerlightoffveryslow
Burnerlightoffveryslowly
Color stays dull
Burnerflashback
(roaringnoiseduringoperation
andceramicgridsurfacewillbedark)
Ceramic grid or burner sooting up
(whenneworaftercleaning)
Pilotcannotbeignited
Pilotlightsbutgoesout
Pilotstayslitbutmainburnerwillnotlight
Failuretoignite
HIGH ALTITUDE OPERATION
1. PleasecontactthefactoryforadetailedHighAltitude
ConversionKittosuityourspecificneed.
1.1Bepreparedtoanswerfactoryquestions
regarding:Typeoffuelfortheproposedappliance
conversion,gaspressureavailableatsite,andspecific
altitude at site.
2. "Theconversionshallbecarriedoutbya
manufacturer'sauthorizedrepresentative,
inaccordancewiththerequirementsofthe
manufacturer,provincialorterritorialauthorities
havingjurisdictionandinaccordancewiththeir
requirements."
3. HighAltitudeConversionKitswillincludehigh
altitude rating plate with stamped data, necessary
orificesorburnerasrequiredforspecificneedand
additional installation instructions.
4. InCanada,HeaterinstallationsatHighAltitudesshall
complywiththeapplicableconstructionprovisionsof
thecurrentstandardCAN1-2.17,gasfiredappliances
for use at high altitudes.
Enerco Group, Inc. | Gas-Fired Infra-Red Space Heaters
gaspressureisavailabletotheheaterandthatthelighting
procedure is as stated on the plate attached to the heater.
CAUSES
Partiallyblockedpilotorifice
Pilot out of adjustment
Partiallyblockedburnerorifice
Lowgaspressure
Damagedburner
Firstcheckfordamaged
burner orifice
Ifburnerorificeisnotdamaged
thencheckfordamagedmanifold.
Blockedpilotorifice
Gascocknotinposition
Pilotgasflowadjustmentscrewmaybeclosed G ascontrolknobmustbeturnedtopilot
Defectivethermocouple
Defectivecontrol
Loosewireorimproperlywired
Defectivecontrol
Blockedburnerorifice
Maingasoff
Airingasline
Loosewireconnections
Dirty wire connections
E7
Operating Instructions and Owner's Manual
SOLUTIONS
Re-adjustpilot
Replace
Replace
Correctlinepressureorcallyourgas
supplier
Replace
Replaceifdamaged
Replace
Replace
and held depressed
Openandadjust(seeFigure8)
Replace
Replace
Tightenconnections,checkwiring
diagram
Replace
Clean orifice or replace
Openmanualvalves
Bleedgasline
Tightenwireconnections
Clean terminals and secure terminals