Maintenance and cleaning of the stove STAVANGER 8/
TROMVIK 8/ LILAND 8/ ULVIK 8/ ULVIK 10
Before effecting any maintenance operation or cleaning on the stove, take the following
precautions:
• Be sure that all parts of the stove are cold.
• Be sure that the ashes are completely cold.
• Be sure that the general switch is in the "OFF" position.
• Be sure that the plug is pulled out of the socket to avoid accidental contact.
• Once the maintenance phase is completed check that everything is in order as per before the
intervention (the brazier is placed correctly).
Follow carefully the following cleaning instructions. Failure to follow these
instructions could create problems with the operation of the stove.
Cleaning the brazier and brazier support
When the flame assumes a red colour or seems weak, and is accompanied
by black smoke, this means that there are ash deposits or incrustations
that do not permit the correct functioning of the stove and that must
be removed (Pict. 11). Remove the brazier every day by simply raising it
from its slot; then clean out the ashes and eventual incrustations that may
have formed, paying particular attention to liberating the holes by using a
pointed tool (not included with the stove).
This operation is made particularly necessary before every lighting the first
several times and above all if using pellets that differ from those supplied
by our company. The frequency of this operation is determined by how
frequently the stove is used and the choice of pellets.
It is also a good idea to check the brazier support, vacuuming the eventual
ash present.
6.7 Pulizia giornaliera tramite raschiatore (ove presente)
Daily cleaning with a scraper (if supplied)
With the stove shut down and chill, activate the scraper in the heat exchange ducts by pushing and
collocata tra le griglie frontali da dove fuoriesce l'aria ambiente.
pulling the lever, located between the frontal grates where the environmental air exits, backwards and
forwards 5 or 6 times.
• Push the scraper towards the stove with the door closed (Pict. 12).
• Pull the scraper outwards with the door closed (Pict. 13).
Pict. 12: deactivated scraper
83
Pict. 13: activated scraper