This appliance is intended for
connection to fixed wiring. Check
that the electrical rating shown on
each fan matches the mains supply.
THE APPLIANCE IS DOUBLE INSULATED
AND DOES NOT REQUIRE AN EARTH
CONNECTION.
All installations must be supervised by a
qualified electrician. Installations and wiring must
conform to current IEE Regulations (UK), local or
appropriate regulations (other countries).
This appliance can be used
by children aged from 8 years
and above and persons with
reduced physical, sensory
capabilities or lack of
experience and knowledge
if they have been given
supervision or instruction
concerning the use of the
appliance in a safe way and
understand the hazards
involved. Children shall not
play with the appliance.
Cleaning and maintenance
of the appliance shall not be
made by children.
All Xpelair Simply Silent™ DX150 AC
fans have the following features:
• Two speed extraction
(Selectable at installation)
• Built-in back draught shutter
DX150S/DX150R - Operate the fan using an
on/off switch (not supplied).
DX150PS/DX150PR - Operate the fan using an
integral pull-cord.
DX150TS/DX150TR* - Built-in timer operates fan
for a preset delay from 30 seconds to 30 minutes.
DX150HTS/DX150HTR* - Operates when triggered
automatically by the integral humidity sensor, or by
using an external on/off switch (not supplied).
In automatic mode: the built-in timer automatically
operates the fan for a pre-set delay time from 30
seconds to 30 minutes once humidity drops below
the pre-set Relative Humidity (RH) value.
External operation: When switched off using the
external on/off switch the fan continues to run for
the preset delay from 30 seconds to 30 minutes.
* Factory settings: Timer 15 minutes, RH 75%
Where to locate the fan.
• Locate it as high as possible.
• At least 110mm from the edges of
from and opposite to the main source of air
replacement to ensure airflow across the
room (e.g. opposite the internal doorway).
• Near the source of steam or odours.
• If installing in a room containing a fuel
burning device which has a non-balanced
flue, it is the installer's responsibility to
ensure that there is enough replacement air
to prevent fumes being drawn down the flue
when the fan is operating up to maximum
extract. Refer to Building Regulations for
specific requirements.
• Exhaust air must not be discharged into
a flue used for exhausting of fumes from
appliances supplied with energy other than
electric. Requirements of all authorities
concerned must be observed for exhaust air
discharge and intake flow rates.
• Not suitable for use in possible chemical
corrosive atmospheres.
If wall mounting the fan, you will also need:
• A 150mm diameter prepared hole.
• An appropriate external Wall Grille and
Ø150mm wall sleeve duct. Kit Ref 91233AW.
If ceiling mounting the fan, you will also need:
• A 150mm diameter prepared hole.
• Appropriate ancillaries for termination. These
items are available from Xpelair:
• 3m flexible ducting Ref: 89665AA. If the duct
passes through a cold space use insulated
duct ref: 91461AA.
the mounting surface to the centre
of the hole.
As far away as possible
• Not where ambient temperatures
are likely to exceed 50°C.
• If installed in a kitchen
fans must not be mounted
immediately above a cooker
hob, or eye level grill.
What the installer will need.
• 3mm electrician's screwdriver
and No.1 or 2 Pozidrive
screwdrivers.