8.
Remove fluff from the entire filter area.
It is best to use a vacuum cleaner for this
purpose.
9.
Press both journals of the large mesh
filter into the brackets on the loading
door until they snap into place.
10. Re-insert fine strainer.
11. Press against the large mesh filter until
it locks into the interlock.
If the fine strainer is not fitted, the large mesh
filter will not snap into place and the loading door
cannot be closed.
Cleaning the door seal
Wipe the door seal with a damp cloth immediately after the drying cycle has finished.
Emptying the condensate tank
Empty condensate tank after every drying cycle.
If the condensate tank is full, an active programme will break off automatically and the
warning led light up. In order to continue the programme, the condensate tank must first
be emptied.
WARNING!
The condensate is not suitable for drinking or for preparing foodstuffs.
1. Take out drawer containing condensed
water container completely 1 and pull up
the condensed water container's drain-
age pipe as far as it will go 2 .
Care and cleaning
1
15
2