Putting Into Operation; Periodical Maintenance - IARP Gamma 150 Instructions D'emploi Et D'entretien

Masquer les pouces Voir aussi pour Gamma 150:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11

PUTTING INTO OPERATION

Check that the voltage on the identification plate is the same as that of the network.
THE ELECTRICAL SUPPLY LINE TO WHICH THE REFRIGERATOR WILL HAVE
TO BE CONNECTED IS TO BE PROTECTED BY
A VERY SENSITIVE DIFFERENTIAL SWITCH
(Rc=16A,Dc=30mA); IT IS ALSO TO BE LINKED TO
THE GENERAL EARTHING PLANT.
The manufacturer disclaims all responsability for any damage
to people or things due to incorrect observance of this rule.
Earthing is necessary and compulsory by law.
Absolutely never use reduction units, patch cords, adap-
ters or multiple socket outlets to connect the counter.
DIRECTLY connect the equipment to the mains.
After plugging, wait till the appliance reaches the right
temperature before filling it; don't place the product over
the max. load level.

PERIODICAL MAINTENANCE

Any further adjustments on the refrigerator necessarily require the electric plug to be removed.
Check periodically the supply cable in order to detect any damage.
If the power supply cable is damaged, don't use the equipment and don't try to repair it: to prevent any
risk, it must be replaced by the manufacturer, by a member of the after-sales service staff, or anyway
by a person having similar qualifications.
In any case, none of the protective elements (the grill, the carter) must be removed by non qualified
staff. Absolutely avoid using the refrigerator without such protection.
The replacement of neon tubes (GAMMA S) must be carried out only by an Authorized Service
Center.
MANUAL DEFROSTING AND TANK CLEANING
To always reach the highest efficiency, the refrigerator needs manual defrosting whenever the frost is
over 5 mm thick. Proceed as follows:
1) Place the product in special refrigerated containers,
kept at the same temperature.
2) Take the plug out.
3) Put a basin of warm but not boiling waterinto the tank
and close the glass lids for about 30 minutes.
4) Rotate the lower draining tubes externally, take the
draining taps off from the inner tank and from the tubes
and put a basin under them to collect water.
5) Carefully wash the tank with water and neutral soap;
rinse and dry well.
6) Plug in again and wait till the appliance reaches the
right temperature before filling it again.
Do not use jet of water to clean the cabinet: electrical wiring could be damaged.
Never use mechanical devices or any other means to accelerate the defrosting process, other than
those recommended by the manufacturer.
-8-

Publicité

Table des Matières
loading

Table des Matières