Features
ELECTRONIC CONTROL
INSTRUCTIONS
POWER button
1
Turns power on/off.
SLEEP button
2
Used to initiate the SLEEP operation.
FAN button
3
Controls the fan speed. Press to toggle between three fan
speeds: LOW (press 1 time), MEDIUM (press 2 times) and
HIGH (press 3 times). The fan speed indicator light indicates
the corresponding fan setting. Press the button a fourth time to
initiate AUTO-FAN mode. In this mode, all three indicator lights
will light up.
4
UP and DOWN buttons
Used to adjust (increase / decrease) temperature settings
(1°C/1°F increments) in a range of 17°C(62°F) to 30°C(86°F)
or the TIMER setting in a range of 0~24hrs. The control is
capable of displaying temperature in degrees Fahrenheit or
degrees Celsius. To convert from one to the other, press and
hold the Up and Down buttons at the same time for 3 seconds.
5
MODE select button
Selects the appropriate operating mode. Each time you press
the button, a mode is selected in a sequence that goes from
AUTO, COOL, DRY, FAN and HEAT. The mode indicator light
illuminates depending on the mode settings.
TIMER button
6
Used to initiate the AUTO ON start time and AUTO OFF stop time program,
in conjunction with the up & down buttons.
7
SWING button
(select models only) Used to initiate the Auto swing feature. When
operating press the SWING button to stop the louver at the desired angle.
8
LED DISPLAY
Shows the set temperature in °C or °F and the Auto-timer settings.
While on DRY and FAN modes, it shows the room temperature.
Error codes:
E1 - Room temperature sensor error -Unplug the unit and plug
it back in. If error repeats, call for service.
E2 - Evaporator temperature sensor error- Unplug the unit and
plug it back in. If error repeats, call for service.
E3 - Condenser temperature error - Unplug the unit and plug it
back in. If error repeats call for service.
E4 - Display panel communication error - Unplug the unit and
plug it back in. If error repeats call for service.
P1 - Bottom tray is full - Connect the drain hose and drain the
collected water away. If error repeats, call for service.
6