English
Charging Level Indicator
RED LED shows that the battery is in the initial charging phase.
100%
YELLOW LED shows that the battery charger has reached 80% of charge.
80%
80%
GREEN LED shows that the battery has reached 100% of charge.
START
Further information can be found in the description of the Charging Curve.
Line Alarm Indicator
This RED LED turns on when there is a phase missing on the mains.
In this situation the battery charger will not operate and the charging level indicator changes to yellow.
(Check mains and input fuses).
LINE
ALARM
Alarms (Two-tone audible message)
An two-tone audible message and the flashing LED shows that an Alarm situation has occurred:
Condition
Audible message +
RED flash
Audible message +
YELLOW flash
Audible message +
GREEN flash
Audible message +
RED-YELLOW flash
Audible message +
RED-GREEN flash
Audible message +
YELLOW -GREEN flash
Audible message +
RED-YELLOW-GREEN flash
When there is an alarm the battery charger stops supplying current.
Thermal Sensor and/or External Indicator
Auxiliary Inputs/Outputs
Connector Mini-Fit 16 poles
16 15 14 13 12 11 10 9
8 7 6 5 4 3 2
N°
1
AUX 1 NC
2
AUX 1 C
3
AUX 1 NO
4
AUX 2 NC
5
AUX 2 C
6
AUX 2 NO
7
S/S HW (cut R100)
8
S/S HW (GND)
Unless otherwise stated, the auxiliary contacts provide the following functions:
Section
AUX1
Mains Presence
AUX2
End of charge or Trickle Phase
S/S HW
Remote ON/OFF command.
(Start/Stop hardware)
8
Battery charger NGTOP
Alarm Type
Battery Presence
Battery disconnected or not in conformity. (Verify the connection and the nominal
voltage).
Thermal Sensor
The thermal sensor is disconnected during the re-charge or it is out working range.
(Verify the connection of the sensor and measure the temperature of the battery).
Timeout
Phase 1 and/or Phase 2 have a duration in excess of the maximal allowed. (Verify the
battery capacity).
Battery Current
Loss of output Current control. (Failure of the control logic).
Battery Voltage
Loss of output Voltage control. (Battery disconnected or failure of the control logic).
Selection
An unavailable configuration has been selected (Verify the selector's position)
Thermal
Overheating of semiconductors. (Verify the fan operation).
Thermal Sensor and/or External Indicator are Options that have to be connected to the 5 poles socket 180° .
Unless otherwise stated, the compensation of the Battery Voltage in function of the temperature of the
Thermal Sensor is of -5mV/° C for battery cell.
The control range of the Thermal Sensor goes from -20° C to +50° C.
The External Indicator reflects exactly the LED Indicator which is placed on the equipment.
Further information can be found in the description of the Charging Curve.
1
Description
Function
When the equipment is switched on, the contact Normally Open (NO) CLOSES
and instead the contact Normally Closed (NC) OPENS.
When the Stop Phase or the No Stop Phase is reached, the contact Normally
Open (NO) CLOSES and instead the contact Normally Closed (NC) OPENS.
Closing contacts allow charger functioning, opening contacts stop charger; stop
condition is indicated by a yellow LED.
Description (Action)
Technical Features:
changeovers contacts
0,3A 125 V
0,3A 110 V
1A 30 V
N°
9
10
11
12
13
14
15
16
AC
DC
DC
Description
Available for accessories
For future development
For future development
For future development
For future development
For future development
For future development
Available for accessories
Description
D01090-15