7.5.6.2 Firmware/Reset

Firmware/remote upgrade:
Restart:
Reboot schedule:

7.5.6.3 Log file

Log file:
data relevant to the system is recorded in the log file. This can help with
troubleshooting, for example.
Export:
exporting the log file into another file

7.5.6.4 RS-485 (only IPCA53000)

In this menu item the parameters for the RS485 control interface can be set. An application
scenario is as a IPCA53000 Box Type Camera installed on a pan / tilt head. The camera can be
connected via the RS-485 interface with the pan / tilt head, and the camera can pan / tilt send
commands to the pan / tilt head. This function can be used only in conjunction with the ABUS
CMS software (not via the web interface of the camera).
Baud rate
Data bits:
Stop bit:
Parity:
Flow control:
PTZ protocol:
PTZ address:
This function can be used to update the camera's firmware.
First, download the current firmware from the ABUS website.
The "Search" button can be used to select this file for
updating. Press the "Upload" button to start the update.
Press the "Reboot" button to complete the restart manually.
enables scheduled reboot. The reboot can be carried out
every x days at a certain time.
baud rate setting
setting the number of bits used
setting the number of stop bits
parity setting
setting for the use of flow control
PTZ control protocol via RS-485, standard Pelco-D
Setting the user's PTZ address in the RS-485 bus (each device must have
its own PTZ address obtained (PTZ ID). The control unit in bus receives the
ID = 0.