When working with the machine, always hold it firmly with both hands
and provide for a secure stance.
For further safety instructions, please refer to the enclosure!
Before starting the machine check the correspondence between voltage and
frequency according to the data mentioned on the identification plate.
Voltage differences from + 6 % and – 10 % are allowed.
The wall chaser is made in protection class II.
Only use extension cables with a sufficient cross-section. A cross-section
which is too small could cause a considerable drop in performance and an
overheating of machine and cable.
The tool is equipped with a start-up speed limiter to prevent that swift
automatic circuit breakers are unintentionally triggered.
Recommended minimum cross sections and maximum cable lengths
Mains voltage Cross section in sq. mm
1.5
110V
-
230V
50 m
Switching on and off
The wall chaser EMF 125 is equipped with a lock-off button against
unintentional switch-on.
1
2
Fig.1
Instructions for Use
Exercise caution when cutting slots in supporting walls; see section
"Information on structural calculations".
Do not strain the machine so heavily that it comes to a standstill.
Only use the Wall chaser dry cutting.
Adjust the cutting depth see section "Pre-selection the Cutting Depth". To
compensate inaccuracies that occur when breaking away the fin, the cutting
depth must be set approx. 3 mm deeper than the requested slot depth.
Electrical Connection
2.5
40 m
80 m
Switching-on: push the lock-off button forward (1) and
then the on/off switch down (2)
Switching-off: release the on/off switch
20