b. Remove the grease filters (see paragraph Maintenance) Fig. 11 being sure that the connector of the
mains cable is correctly inserted in the socket placed on the side of the fan. Before fitting the chimney
to the canopy make the electrical connection as described in the section titled ELECTRICAL. When
the electrical connection has been made, test the lights and the fan motor.
c. Follow the instructions Fig. 8 to 3.
IN THE RECIRCULATION MODE:
a.
Fit the recirculation spigot R onto the upper chimney wall bracket using the same fixing screws
(Fig. 12).
b. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot
and secure the connections with appropriate clamping rings or adhesive tape.
c. Remove the grease filters (see paragraph Maintenance) Fig. 11 being sure that the connector of
the feeding cable is correctly inserted in the socket placed on the side of the fan. Before fitting the
chimney to the canopy make the electrical connection as described in the section titled ELECTRI-
CAL. When the electrical connection has been made, test the lights and the fan motor.
d. Insert the charcoal filter into the base of the motor housing and secure the filter with two metal secur-
ing straps item A as illustrated in Fig. 13.
e. Follow the instructions Fig. 8 to 3.
GB