INTERIOR-MOUNTED VENT MOTOR
Determine which venting method is best for your application.
Vent system can terminate through either the wall or floor.
Island location
A. Down vent
Built-in cabinet locations
A
C
A. Down vent
B. Rear vent
8
INSTALLATION INSTRUCTIONS
Venting Methods - Interior Mounted Vent Motor Only
A
B
C. Left vent
D. Right vent
Island Location
Vent system installed under a concrete slab using PVC
sewer pipe.
A
M
L
A. Wall cap
B. 6" (15.2 cm) round metal vent
C. 16" (40.6 cm) maximum
D. 6" (15.2 cm) round PVC sewer pipe
E. 6" (15.2 cm) round metal vent
F. 6" (15.2 cm) round PVC coupling
G. Concrete slab
H. 6" (15.2 cm) round PVC sewer pipe
I. 6" (15.2 cm) round 90° PVC sewer pipe elbow
J. Tightly pack gravel or sand completely around pipe.
K. 6" (15.2 cm) round 90° PVC sewer pipe elbow
L. 6" (15.2 cm) round PVC coupling
M. 12" (30.5 cm) minimum
Calculating Vent System Length
It is recommended that you use round vent instead of rectangular
vent, especially if elbows are required. If rectangular vent is
required, it should be transitioned to 6" (15.2 cm) round vent as
soon as possible.