Connecting leads that are run underground shall be run in conduit
of insulating material or else insulated high voltage cable shall be
used. Care must be taken to avoid damage to the connecting leads
due to the effects of animal hooves or vehicle wheels sinking into
the ground.
Connecting leads shall not be installed in the same conduit as the
mains supply wiring, communication cables or data cables.
Connecting leads and electric fence wires shall not cross above
overhead power or communication lines.
Crossings with overhead power lines shall be avoided wherever possi-
ble. If such a crossing cannot be avoided it shall be made underneath
the power line and as nearly as possible at right angles to it.
If connecting leads and electric fence wires are installed near an
overhead power line, the clearances shall not be less than those
shown in the table below.
Minimum clearances from power lines for electric fences
Power line voltage
≤1,000 V
>1,000 V bis ≤33,000 V
>33,000 V
If connecting leads and electric fence wires are installed
near an overhead power line, their height above the ground
shall not exceed 3 m. This height applies to either side of
the orthogonal projection of the outermost conductors of the
power line on the ground surface, for a distance of:
• 2 m for power lines operating at a nominal voltage
not exceeding 1,000 V.
• 15 m for power lines operating at a nominal voltage
exceeding 1,000 V.
Electric fences intended for deterring birds, household pet
containment or training animals such as cows need only be
supplied from low output energisers to obtain satisfactory
and safe performance.
In electric fences intended for deterring birds from roosting
on buildings, no electric fence wire shall be connected to the
energiser's earth stake.
Clearance
3 m
4 m
8 m
w w w. p a t u r a . c o m
Ensure that all mains-operated, ancillary equipment
connected to the electric fence circuit provides a degree of
isolation between the fence circuit and the supply mains
equivalent to that provided by the energiser.
Protection from the weather shall be provided for the
ancillary equipment unless this equipment is certified by the
manufacturer as being suitable for use outdoors, and is of a
type with a minimum degree of protection IPX4.
36 month warranty from
date of purchase
This warranty does not cover defects caused by:
• Incorrect input voltage or polarity
• Damage to external wiring
• Physical mishandling
• Water immersion
• Vermin or insect damage
• Lighning strike
Note: This product has been manufactured to
comply with international safety standards.
This product is warranted against faulty material and work-
manship for a period of 36 calendar months FROM DATE OF
PURCHASE. If a warranted defect occurs, return this product
with proof of purchase to an authorised service centre.
Note:
- No responsibility is accepted for any accident or damage
caused subsequent to any tampering with or modification
to or misuse of this product, including (but not limited to)
unauthorised alterations
- To the maximum extent permitted by law, this warranty is
exclusive, personal to you and in lieu of all other warran-
ties, representations or conditions relating to this product
(whether express or implied and whenever arising) whether
originating by statute, law, trade, custom or otherwise.
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

P 200P 300146100146200146300

Table des Matières