Enter in the parameters menu by pressing 10 seconds on the
(Ok) key, now search the "rF init" parameter with (►) key,
then press again on the (OK) key to enter in the "rf init"
mode.
The following message must appear on the display:
- The number in front of the "init" text corresponds to the
selected zone. (The corresponding LED on the MASTER RF
must blink in green)
- Use (◄) & (►) keys to change the zone (01 to xx), the
green LED blinking cursor move in a same way of the zone
number.
- With (OK) key you can select or de-select the zone(s) which
must be linked with a thermostat. The corresponding LED of
the selected zone(s) must shine in red to indicate that this
zone(s) is waiting for a thermostat signal.
b)
When you have correctly selected the zones which must be
assigned with a RF thermostat go to the thermostat and
activate the "rF init" mode. (See the corresponding leaflet of
the RF thermostat to do this).
c)
Now the thermostat will send the learning message to the
MASTER-RF, Check the good reception on the MASTER-RF,
- 2 squares scrolls on the graphic scope indicate a correct RF
signal.
- The LED previously selected (in RED) must now shine in
green to indicate that the zones are correctly configured with
the thermostat.
- You can now switch off the thermostat to avoid perturbation
during the installation of the other thermostats.
d)
Only when you have finished the configuration of all
thermostats with the MASTER-RF.
Choose now if you need the zone(s) which must be managed
by the main zone programmer. (see point a))
On the main zone programmer go to the "RF menu" and
press on the button to show the 1
Choose now the line "Master" the following screen must be
displayed,