OPERATION

WARNING: To reduce the risk of serious personal
injury, turn unit off and remove the battery pack
before making any adjustments or removing/
installing attachments or accessories. An
accidental start-up can cause injury.

Installing and Removing the Battery Pack

(Fig. E)
nOTE: For best results, make sure your battery pack is
fully charged.
To install the battery pack 
 13 
battery pack with the rails inside the tool's handle and slide
it into the handle until the battery pack is firmly seated in
the tool and ensure that it does not disengage.
To remove the battery pack from the tool, press the release
button 
and firmly pull the battery pack out of the tool
 14 
handle. Insert it into the charger as described in the charger
section of this manual.
Fig. E
Proper Hand Position (Fig. F)

WARNING: To reduce the risk of serious personal injury,
ALWAYS use proper hand position as shown.

WARNING: To reduce the risk of serious personal
injury, ALWAYS hold securely in anticipation of a
sudden reaction.
Fig. F

Mode Selection


WARNING: Always wear proper eye [ANSI Z87.1
(CAN/CSA Z94.3)] and ANSI S12.6 (S3.19) hearing
protection when operating tool.
The D
WALT cordless staplers are assembled in accordance
e
with the ANSI Standard SNT-101-2002.
10
into the tool handle, align the
13
14
The finish stapler is capable of firing staples using bump
actuation or sequential actuation. If you would like to
have the bump actuation mode disabled, have the tool
serviced by an authorized D
e
operating this tool, look at the selector switch to determine
the actuation mode. Read all instructions before selecting
actuation mode.

WARNING: Keep fingers AWAY from trigger when not
driving staples to avoid accidental fastener discharge.
NEVER carry tool with finger on trigger. In bump
mode tool will drive a staple if contact trip is bumped
while trigger is depressed.
Sequential Actuation
Use sequential actuation mode for intermittent stapling
where very careful and accurate placement and depth
control is desired. The sequential actuation mode
provides the maximum delivery of power for driving the
longest staples.
To operate the stapler in sequential actuation mode:
1. Slide the selector switch 
icon 
.
2. Fully depress nosepiece against the work surface (motor
will start).
3. Pull trigger (staple will drive into work surface).
4. Release trigger.
5. Lift nosepiece off work surface.
6. Repeat steps 2 through 4 for next application.
NOTICE: The contact trip needs to be depressed
followed by a trigger pull for each staple followed by
a release of both the contact trip and trigger after
each staple.
Fig. G
Bump Action
(Fig. G)
Bump action is intended for rapid stapling on flat, stationary
surfaces and typically most effective for applications that
require driving shorter staples.
When the tool is set in the bump actuation mode, two
methods of tool operation are available: place actuation and
bump actuation.
Slide the selector switch 
 7 
to expose the triple staple 
icon
.
To operate the tool using the place actuation
method:

WARNING: A staple will be driven each time the
trigger is depressed as long as the contact trip
remains depressed.
1. Depress the contact trip against the work surface.