OPERATION AND LOGIC
1
2
IGNITION
Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove. 15 minutes are given for the ignition
stage, after ignition and once the control temperature has been reached, the stove interrupts the ignition phase and switches to the START-UP
mode.
STARTING
During the start-up stage, the stove stabilises combustion, increasing it gradually, to then start ventilation and switch to the WORK mode.
WORK
During the work stage, the stove reaches the set power and works to reach the set room temperature. See following item.
SET THERMOSTAT ADJUSTMENT
The room temperature setting can be set using buttons 4 and 5, from Low-07 to 40°C -Hot
LOW HOT
If the temperature setting is on "Low" (set below the 7°C threshold) the stove will always function at minimum.
If the setting is on "Hot" (set above the 40°C threshold) the stove will not modulate, always functioning and only at the set power.
SET POWER ADJUSTMENT
Set the functioning power from 1 to 5 (settable using keys 2 - 3).
Power 1 = minimum level - Power 5 = maximum level.
WORK WITH ROOM PROBE STANDARD
The appliance controls the room temperature via a probe tted on the appliance.
Once the the set temperature has been reached, it will automatically go to minimum or switch o activating the Stand by function, reducing
pellet consumption to a minimum.
By default the STBY function is always set on OFF (light
For its activation and logic, follow the indications on the next page, chapter: Stand by.
BURN POT CLEANING
During the work stage, the stove has an internal counter which cleans the burn pot after a set amount of time.
This stage will be shown on the display, it will bring the stove to a lower power level and will increase the fumes motor for a programmed
amount of time.
When the cleaning stage is nished, the stove will continue its work, going back to the selected power level.
SWITCH OFF
Press key 1 for three seconds.
When the operation has been performed, the appliance automatically enters the switch- o phase, blocking the supply of pellets.
The fumes motor and the hot air ventilation motor will remain on until the temperature of the stove has dropped below the factory
parameters.
RE IGNITION
The stove can only be re-ignited if the ue gas temperature has lowered and the preset timer has been reset to zero.
DO NOT USE ANY INFLAMMABLE LIQUIDS FOR IGNITION!
DO NOT ALLOW THE BAG OF PELLETS TO COME INTO CONTACT WITH THE BOILING HOT STOVE DURING THE FILLING
PHASE!
IN THE EVENT OF CONTINUOUS NO IGNITION, CONTACT AN AUTHORISED TECHNICIAN.