Ducane 20529916 Guide De L'utilisateur page 22

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ANNUAL MAINTENANCE
ANNUAL MAINTENANCE
You can now lift out a burner tube for inspection.
If there is dust or dirt on the screens, brush the spider/insect screen(s), lightly, with a
soft bristle brush, (i.e. an old toothbrush).
CAUTION: Do not clean the spider/insect screens with hard
or sharp tools. Do not dislodge the spider/insect screens or
enlarge the screen openings.
If the spider/insect screen becomes damaged or cannot be cleaned, call Ducane Cus-
tomer Service at 1-800-382-2637 for replacement parts.
To reassemble, reverse steps 2 through 5.
Cleaning the Spider/Insect Screens
Your Ducane
®
gas barbecue, as well as any outdoor gas appliance, is a target for spiders
and other insects. They can nest in the venturi section (1) of the burner tubes. This
blocks the normal gas fl ow, and can cause the gas to fl ow back out the air shutter. This
could result in a fi re in and around the air shutters, under the control panel, causing
serious damage to your barbecue.
The burner tube air shutter is fi tted with a stainless steel screen (2) to prevent spiders
and other insects access to the burner tubes througth the air shutter openings.
We recommend that you inspect the Spider/Insect screens at least once a year. Also,
inspect and clean the Spider/Insect screens if any ot the following symptoms occur:
1. The smell of gas in conjunction with the burner fl ames appearing yellow and lazy.
2. Barbecue does not reach temperature.
3. Barbecue does not heat evenly.
4. One or more of the burners do not ignite.
DANGER: Failure to correct the above mentioned symptoms
may result in a fire, which can cause serious bodily injury or
death, and cause damage to property.
Main Burner Flame Pattern
®
The Ducane
gas barbecue burners have been factory set for the correct air and gas
mixture. The correct fl ame pattern is shown.
1. Burner tube
2. Tips occasionally fl icker yellow
3. Light blue
4. Dark blue
If the fl ames do not appear to be uniform throughout the burner tube, follow the main
burner cleaning procedure.
22
1
2
www.ducane.com

Publicité

Table des Matières
loading

Table des Matières