FIXTURE HOURS
T o select Fhrs, press the ENTER button to show the FIXTURE HOURS on the display and the display will show the
number of working hours of the unit . T o go back to the functions without any changes press the MENU button again.
Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
SOFTWARE VERSION
T o select Ver, press the ENTER button to show the SOFTWARE VERSION on the display and the display will show
the version of software of the unit . T o go back to the functions without any changes press the MENU button again.
Hold and press the MENU button for one second or wait for one minute to exit the menu mode.
RESET
T o select rSet, press the ENTER button to show the RESET on the display. Press the ENTER button and all channels
of the unit will return to their standard position.
OPERATING
MASTER SLAVE OPERATING
By linking the units in master/slave connection, the first unit will control the other units to give an automatic, sound
activated, synchronized light show. This function is good when you want an instant show. You have to set the first
unit in master mode M a s t and select S p 0 (random show),
input jack will have nothing plugged into it, and its master LED will be constantly on and sound LED will flash to the
music. The other units will have to select Sl1 (normal) or Sl2 (2 light show) mode, Their DMX cables plugged into
the DMX input jacks (daisy chain) and the slave LED lights will be constantly on.
SOUND OPERATING
- Set fixture as " MAST"
- Set "SHND" as "Sp 0"
- Set "SOUD" as "ON"
- Set "SENS" as " 50-60" ( if you make "0", sound control model is switched off )
- Set "BLND" as " ON"
DMX OPERATING
Using a universal DMX controller to control the units, you have to set DMX address from 1 to 512 channel so that
the units can receive DMX signal.
Press the MENU button up to when the Addr is showing on the display. Press ENTER button and the display will
blink. Use DOWN and UP button to change the DMX512 address. Once the address has been selected, press and
keep ENTER button pressed up to when the display stops blinking or storing automatically 7 seconds later. T o go
back to the functions without any change press the MENU button again.
© Copyright LOTRONIC 2015
Sp1 (show 1) or ...or S p 9 (show 9). Its DMX
MINI-BEAMWASH
Page 7