Maintenance Instructions; Moving And Storage Instructions; Troubleshooting - Schumacher Electric SJ1427 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING: RISK OF ELECTRIC SHOCK.
Incorrect operation of your converter may result in damage and personal injury. The converter output is
120V AC and can shock or electrocute the same as any ordinary household AC wall outlet.
NOTE: The maximum continuous load is 200 watts. Do not use the converter with a product that draws
more than 200 watts, as this may cause damage to the converter and the product.
6.

MAINTENANCE INSTRUCTIONS

After use and before performing maintenance, unplug and disconnect the jump starter.
6.1
Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery clips, cords and the
6.2
jump starter case.
Ensure that all of the jump starter components are in place and in good working condition.
6.3
6.4
All servicing should be performed by qualified service personnel.
7.

MOVING AND STORAGE INSTRUCTIONS

Store inside, in a cool, dry place.
7.1
Do not store the clips on the handle, clipped together, on or around metal, or clipped to cables. The clips
7.2
on the jump starter are live when the switch is in the ON position and will produce arcing or sparking if
they come in contact with each other. To prevent accidental arcing, always place the switch in the OFF
position and keep the clips on the storage holders when not using it to jump start a vehicle.
If the jump starter is moved around the shop or transported to another location, take care to avoid/
7.3
prevent damage to the cords, clips and jump starter. Failure to do so could result in personal injury or
property damage.
IMPORTANT: Do not use and/or store the jump starter in or on any area or surface where damage
could occur if the internal battery should unexpectedly leak acid.
IMPORTANT:
7.4
• CHARGE IMMEDIATELY AFTER PURCHASE
• KEEP FULLY CHARGED
Charge the jump starter's internal battery immediately after purchase, after every use and every 30 days.
All batteries are affected by temperature. The ideal storage temperature is at 70°F. The internal battery will
gradually self-discharge (lose power) over time, especially in warm environments. Leaving the battery in a
discharged state may result in permanent battery damage. To ensure satisfactory performance and avoid
permanent damage, charge the internal battery every month.
8.

TROUBLESHOOTING

PROBLEM
The unit won't jump start my car.
POSSIBLE CAUSE
Jump Start/USB switch is not
turned ON.
Clips are not making a good
connection to the battery.
The internal battery is not charged.
The vehicle's battery is defective.
• 11 •
SOLUTION
Turn ON the Jump Start/USB
Switch.
Check for poor connection to
battery and frame. Make sure
connection points are clean. Rock
clamps back and forth for a better
connection.
Check the battery charge status
by pressing the button on the
front of the unit. See Checking the
Level of the Internal Battery.
Have the battery checked.