Sommaire des Matières pour Schumacher Electric INSTANT POWER XPF2260
Page 1
OWNER’S MANUAL GUIDE D’UTILISATION XPF2260 Model / Modèle: INSTANT POWER™ Jump Starter and DC Power Source Aide de Démarrage et Source d’Énergie CC DO NOT RETURN THIS PRODUCT TO THE STORE! Call Customer Service for Assistance: 800-621-5485 NE PAS RETOURNER LE PRODUIT AU MAGASIN! Appeler le service clientèle pour l’assistance: 800-621-5485 READ THE ENTIRE MANUAL BEFORE USING THIS PRODUCT.
Page 2
IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. SAVE THESE INSTRUCTIONS – Charge the Instant Power™ internal battery immediately after purchase, after every use and every 30 days. This manual will show you how to use your Instant Power™ safely and effectively. Please read, understand and follow these instructions and precautions carefully, as this manual contains important safety and operating instructions.
RISk OF EXPLOSIVE GASES. 1.13 WORKING IN THE VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE INSTANT POWER™. 1.14 To reduce the risk of a battery explosion, follow these instructions and those published by the battery manufacturer and the manufacturer of any equipment...
INSTANT POWER™ LOCATION RISk OF EXPLOSION AND CONTACT WITH BATTERY ACID. Locate the Instant Power™ as far away from the battery as the DC cables permit. Never place the Instant Power™ directly above the battery being jumped; gases from the battery will corrode and damage the Instant Power™. Do not operate the Instant Power™...
CHARGING THE INTERNAL BATTERY OF THE INSTANT POWER™ IMPORTANT: CHARGE IMMEDIATELY AFTER PURCHASE, AFTER EACH USE AND EVERY 30 DAYS TO kEEP THE INSTANT POWER™ INTERNAL BATTERY FULLY CHARGED. Check the internal battery’s charge level by pressing the Display Button. The Digital Display will show the battery’s percent of charge.
Determine which post of the battery is grounded (connected) to the chassis. If the negative post is grounded to the chassis (as in most vehicles), see step 6. If the positive post is grounded to the chassis, see step 7. For a negative-grounded vehicle, connect the POSITIVE (RED) clip from the jump starter to the POSITIVE (POS, P, +) ungrounded post of the battery.
The Instant Power™ light will turn on and illuminate your work area. Press the Light Switch to the OFF position. Charge the Instant Power™ as soon as possible after using the built-in light. 10.6 Using the Air Compressor RISk OF EXPLOSION. Read the instructions of the product being inflated before using the compressor.
Page 8
Make sure the Instant Power™ is not close to any potential source of flammable fumes or clothing. Keep the Instant Power™ dry. DO NOT allow the Instant Power™ to come into contact with rain or moisture. DO NOT operate the Instant Power™ if you, the Instant Power™, the device being operated or any other surfaces that may come in contact with any power source are wet.
10.11 Powering a 120V AC Device To operate a 120V AC device: Ensure the battery clips are securely on the storage holders. Open the protective cover of the AC power outlet on the front panel of the Instant Power™. Make sure the 120V AC device to be operated is turned OFF. Plug the 120V AC device into the AC power outlet, and turn the Inverter Switch to the ON position.
Page 10
TROUBLESHOOTING PROBLEM POSSIBLE CAUSE REASON/SOLUTION The Instant Power™ won’t Jump Start/USB Switch is not Turn ON the Jump Start/USB jump start my car. turned ON. Switch. Clips are not making a good Check for poor connection to connection to the battery. battery and frame.
SPECIFICATIONS Internal Battery Type Maintenance-free AGM Lead-acid Nominal Voltage 12V DC Capacity 18 Ah DC Power Outlet (Max. Continuous Load) 15A (both outlets combined) Built-in Work Light (Non-replaceable) 3 white LEDs Jumper Cables 4-gauge AWG, 24 Inches Dimensions (H x W x D) 12 H x 11.5 x 10.5 Inches Product Weight 23.9 lbs.
Page 12
Manufacturer does not provide any warranty for any accessories used with this product that are not manufactured by Schumacher Electric Corporation and approved for use with this product. This Limited Warranty is void if the product is misused, subjected to careless handling, repaired, or modified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer.
Page 13
The warranty card should be submitted within 30 days of purchase. The customer must keep the ORIGINAL receipt because it will be required for any warranty claims. This warranty is not transferable. Mail To: Schumacher Electric Corporation 801 Business Center Drive Mount Prospect, IL 60056-2179 Name_______________________________________________________________...
Page 15
IMPORTANT: LIRE ET CONSERVER CE GUIDE DE CONSIGNES DE SÉCURITÉ ET D’UTILISATION. CONSERVER CES CONSIGNES – Chargent l’Instant Power™ La batterie intérieure immédiatement après l’achat, après chaque utilisation et tous les 30 jours. Ce guide vous montrera comment utiliser votre Instant Power™ efficacement et en toute sécurité. Veuillez lire, comprendre et suivre ces instructions et précautions attentivement sachant que ce guide contient d’importantes consignes d’utilisation et de sécurité.
1.12 Ne pas démonter l’Instant Power™; apportez-le chez un technicien qualifié quand vous devez l’entretenir ou le réparer. Un mauvais remontage pourrait causer un risque d’incendie ou de choc électrique. (Appelez le service à la clientèle au: 1-800-621-5485.) RISqUE DE GAZ EXPLOSIFS. 1.13 TRAVAILLER AU VOISINAGE D’ACCUMULATEUR AU PLOMB EST DANGEREUX.
Nettoyer les bornes de la batterie avant d’utilisée l’unité. Lors du nettoyage, ne laissez pas les particules de corrosion entrer en contact avec vos yeux, votre nez et votre bouche. Utilisez du bicarbonate de sodium et de l’eau pour neutraliser l’électrolyte de batterie et aider à...
L’utilisation de cette méthode de charger la batterie passe au mode maintiens et la batterie peut être surchargée. Contrôlez le progrès de la batterie et quand il atteint une charge (de 100%) complète, débranchez le chargeur. Ne laisser pas la batterie sans surveillance ou il pourrait faire exploser et peut causer du dommage de propriété...
Une fois le moteur démarré, assurez-vous que pour éteindre l’interrupteur Jump Start. Puis débrancher la pince noire (-) puis la rouge (+); dans cet ordre. Recharger l’Instant Power™ aussitôt que possible après utilisation. RISqUES D’EXPLOSION Pour éviter toute étincelle, NE JAMAIS laisser les pinces se toucher ou toucher la même partie métallique.
Une fois le produit gonflé à la pression correcte d’air (enutilisant le manomètre), mettre l’interrupteur Compresseur/Gonfler en position OFF et retirer le flexible. Ne pas utiliser plus de 10 minutes, maxi, à la fois. Laisser l’Instant Power™ refroidir pendant 10 minutes avant de l’utiliser encore. NOTE: Pour éviter toute surchauffe, le compresseur possède une protection thermique intégrée qui éteindra le compresseur avant qu’il ne surchauffe.
Ne pas exposer l’Instant Power™ aux rayons directs du soleil. La température de service idéale est entre 50° et 80°F. Ne pas utiliser l’onduleur à proximité d’un compartiment moteur ouvert où des fumées peuvent s’accumuler. Ne pas modifier les réceptacles CA de quelque façon que ce soit. 10.10 Utilisation de l’Onduleur Il est important de connaître la puissance continue de l’appareil que vous prévoyez...
Si l’appareil ne fonctionne pas correctement dès son premier branchement sur l’onduleur, mettre l’interrupteur à balancier sur ON, OFF et encore sur ON plusieurs fois de suite et rapidement Si cette procédure ne change rien, il est probable que la capacité...
TABLEAU DE DÉPANNAGE PROBLÈME CAUSE POSSIBLE RAISON/SOLUTION L’Instant Power™ ne démarre Jump Start/USB Switch n’est Tourner le sélecteur du Jump pas la voiture. pas allumée. Start/USB. Les clips ne font pas de bonne Vérifiez la connexion à la connexion à la batterie. batterie et à...
SPÉCIFICATIONS Batterie Interne Sans Entretien, AGM Plomb-Acide Tension Nominale 12V CC Capacité 18 Ah CC Sortie (Max. Continue) 15A (deux sorties combinées) Lumière Inclus (remplaçable) 3 DEL blanc Cables Démarrage 4 de calibre AWG, 24 inch Dimensions (H x W x D) 12 H x 11.5 x 10.5 Inches Poids du Produit 23.9 lbs.
Le fabricant ne fournit aucune garantie sur les accessoires utilisés avec ce produit qui ne sont pas fabriqués par Schumacher Electric Corporation et approuvés pour être utilisés avec ce produit. Cette garantie limitée est annulée si le produit est sujet à...