➢ ➢ If a clog prevents the normal flow of air to the motor, the thermal protector turns
the motor off automatically to allow the motor to cool in order to prevent
possible damage to the vacuum cleaner.
➢ ➢ To correct problem, turn off and unplug the vacuum cleaner, remove clogs
and/or clean/replace filters.
➢ ➢ Empty dust bin if necessary.
➢ ➢ Wait approximately thirty (30) minutes, plug vacuum cleaner in, turn on to see if
thermal protector has reset. Thermal protector will not reset if the vacuum
cleaner is not unplugged even if vacuum cleaner cools down.

Cleaning Agitator

➢ ➢ Clean agitator after every five uses.
➢ ➢ Turn vacuum cleaner over, exposing
the agitator.
➢ ➢ Cut off any carpet pile and lint
entangled around agitator with a pair
of scissors.

Thermal Protector