RECCMANDATIONES FOR ADJUSTMENTS
Important
Before making any type of adjustment, acti-
vate all the safety devices provided and de-
cide whether staff at work and those in the
vicinity should be informed.
ADJUSTMENTS BURNER PRIMARY AIR
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Open the hatch (A).
3 - Undo the locking screw (B).
4 - Set the bush (C) at the distance (D) shown in
the table.
5 - Tighten the screw (B).
6 - Close the door (A).
Gas family
II (G 20/20-25mbar)
II (G 25/20-25mbar)
II (G 25.1/25mbar)
III (G 30-31/29-37mbar)
III (G 30-31/50mbar)
RECOMMENDATIONS FOR REPLACING PARTS
Before carrying out any replacement procedure, ac-
tivate all the safety devices provided and decide
whether staff at work and those in the vicinity
should be informed. In particular, turn off the gas
supply tap and prevent access to all devices which
might cause unexpected health and safety hazards
if turned on. If work parts have to be replaced, use
original spare parts only. The manufacturer de-
ADJUSTMENTS
Distance (D)
(mm)
24±1
24±1
24±1
24±1
24±1
REPLACING PARTS
- 19 -
In particular, turn off the gas supply tap and
prevent access to all devices which might
cause unexpected health and safety haz-
ards if turned on.
A
clines all responsibly for injury or damage to com-
ponents due to the use of non original parts, or
extraordinary work on the appliance which may
modify the safety requirements without the manu-
facturer's authorisation. When ordering compo-
nents, follow the instructions provided in the parts
catalogue.
8
C
B
D
IT
GB
DE
FR
9
ES
English