SWITCHING THE BURNER ON AND OFF
The lighting and turning off procedure is as de-
scribed below for both burners.
Lighting
1 - Turn on the gas supply tap.
2 - Press the knob (A) and turn it anti-clockwise
(pos. 1) while at the same time pressing the pi-
ezoelectric ignition knob (B) repeatedly to light
the pilot light.
3 - Keep the knob pressed for about 15 sec. to
prime the thermocouple.
4 - Turn the knob anti-clockwise (pos. 2) to the
temperature required.
Turning off
1 - Turn the knob clockwise (pos. 3) to turn the
burner off.
The pilot light will remain on to allow the burner
to be re-lit.
2 - Press the knob and turn it clockwise (pos. 4) to
turn off the pilot light.
3 - Turn off the gas supply tap.
FILTERING OIL
To carry out this operation, proceed as follows.
Important
Before proceeding, allow the appliance to
cool for 10-15 min., so that the oil reaches a
temperature between 50-120°C.
1 - Open the hatch (A).
2 - .Fit the extension (B) onto the tap (C).
3 - .Place the container (D) and the filter (E), both
available as optionals, underneath the exten-
sion (B).
4 - Turn on the tap (C) to empty the well.
5 - Turn off the tap (C) on completion of the opera-
tion.
Caution - warning
Do not dump oil in the environment; dispose
of it in accordance with the laws in force in
the country of use.