Change the Side burner Orifices
1.
Remove the two screws which pre-assembled on side
burner tube, then lift side burner tube out from side
burner firebox, as shown below.
2.
Use 6 mm socket wrench or 6 mm nut driver to remove
the orifice. Replace with the Natural gas orifice.
IMPORTANT: Check that the orifice is properly installed
inside of the valve.
3.
Reinstall side burner, tighten the side burner orifice brass
connector and side burner tube by using a wrench.
4.
Open the manual shutoff valve in the gas supply. The
valve is open when the handle is parallel to the gas pipe.
5.
Test all connections using an approved noncorrosive
leak- detection solution. Bubbles will show a leak.
Correct any leak found.
6.
For normal operating sequence of the ignition system,
see "Lighting Instructions" on page 9.
14