1.5 TECHNICAL DATA

MODEL
Combination condition
Power Supply
Cooling Capacity *
Power Input at Cooling *
Rated current at Cooling *
EER ref. Standard EN14511 *
SEER ref. Standard EN14825
PdesignC
Heating Capacity *
Power Input at Heating *
Rated current at Heating *
COP ref. Standard EN14511 *
Climate Zone ref. Standard EN14825
SCOP * ref. Standard EN14825
PdesignH
Temp balance Tbiv
Temp use limit Tol
Efficiency class Standard
626/2011 Directive 2009/125/CE
Climate Zone ref. Standard EN14825
SCOP * ref. Standard EN14825
PdesignH
Temp balance Tbiv
Temp use limit Tol
Efficiency class Standard
626/2011 Directive 2009/125/CE
Outdoor unit air flow
Sound pressure level outdoor unit **
Sound power level outdoor unit
Refrigerant
GWP
Charge
Packing dimension outdoor unit
Net weight outdoor unit
Liquid connection (qty x Diameter)
Gas connection (qty x Diameter)
Note:
External air temperature = 35°CDB • Ambient air temperature = 27°CDB / 19°CWB
External air temperature = 7°CDB / 6°CWB • Ambient air temperature = 20°CDB
*: Data referred to the nominal matching reported
** Sound pressure level detected at a distance of 1 m.
18-2
9 + 9
Rated
5280
Min-Max
1130-5570
Rated
1630
Min-Max
150-2000
7,10
Rated
3,24
6,10
5,3
Rated
5570
Min-Max
1795-5865
Rated
1390
Min-Max
300-1650
6,1
Rated
4,01
3,80
4,8
-7,0
-15,0
Cooling
A++
Heating
A
4,80
4,9
2,0
2,0
Cooling
A++
Heating
A++
2200
56
65
1,25
W
920
H
615
D
390
38,5
2x1/4"
2x3/8"
24
27-3
28-4
9 + 9 + 9
7 + 7 + 7 + 7
230/1/50
7920
2960-8500
2050-9850
2450
235-3220
890-3180
13,70
3,23
6,10
7,9
8210
2040-9380
2345-10560
2100
310-2890
770-2750
12,5
3,91
A (average)
4,00
5,6
-7,0
-15,0
A++
A+
B (warmer)
5,10
6,1
2,0
2,0
A++
A+++
2700
54
67
R32
675
1,72
965
775
395
51,5
3x1/4"
4x1/4"
3x3/8"
3x3/8" + 1x1/2"
EN
UM
-
V-Ph-Hz
8200
W
W
2540
W
W
11,3
A
3,23
W\W
6,10
W\W
8,2
kW
8800
W
W
2200
W
W
9,8
A
4,00
W\W
Type
3,80
W\W
6,5
kW
-7,0
°C
-15,0
°C
\
A++
\
A
Type
4,60
W\W
6,9
kW
2,0
°C
2,0
°C
\
A++
\
A++
3800
m
/h
3
61,5
dB(A)
67
dB(A)
Type
tCO2 eq.
2,10
kg
1090
mm
875
mm
500
mm
62,1
kg
n° x inch
n° x inch
Cod. 3QE46140 - Rev.
Cod. 3QE461

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Diamant m 18-2Diamant m 27-3Diamant m 28-4

Table des Matières