Introduction
Thank you for selecting the TidalWave MD250, MD350, MD550, MD750, MD1000,
MD1250, MD1500 or MD2000 series pump. Before using this pump please take a
moment to review this manual.
To avoid an accident do not use the pump in any way other than as described in this
manual. Please note the manufacturer cannot be responsible for accidents arising because
the product was not used as prescribed. After reading this manual keep it as a reference
in case questions arise during use.
Flow
Chart:
(GPH)
MD1000, MD1250, MD1500 and MD2000 pumps include an 1½" adaptor for use with the Triton Check
Valve and Atlantic Plumbing Kits. This adaptor makes the discharge height of the Mag Drive Series
pumps equal to the TW2400 pump. If using a Mag Drive Series pump with the Triton Check Valve,
Colorfalls Kit or Fountain Basin Plumbing kits, please reference the plumbing instructions for a TW2400
as outlined in the installation manuals for these items.
Prior to Operation and Installation
• When the pump is delivered, first perform the following checks:
Check for any damage to pump and power cable that may have occurred during
the shipment.
Check the model number to make sure it is the product that was ordered and verify
the voltage and frequency are correct.
Caution
• DO NOT operate this product under any condition other than those for which it is
specified. Failure to observe this precaution can lead to electrical shock, electrical
leakage, fire, water leakage or other problems.
• The pump is a 110/120 volt 60 Hz pump, please only use with a power supply voltage
within 110-120 volt 60 Hz.
• Never place your hand or any object in or near the inlet opening while this equipment is
operating. If pump inlet is clogged, always turn off the power supply and wait until the
motor is completely stopped before attempting to remove any clogged material.
• Please make sure that the power plug and the AC outlet receptacle are protected and away
from water or pump discharge hose to prevent accidental electric shock or short circuit.
• Always operate the pump completely submerged in water.
• Avoid dry operation, which will not only lower performance but can cause the pump to
overheat/malfunction, leading to electrical leakage, shock or premature failure.
• Always turn off power or unplug the pump prior to performing any maintenance or
placing your hands into the water.
2
Model #
Watts
MD250
15
MD350
25
MD550
40
MD750
50
MD1000
90
MD1250
120
MD1500
165
MD2000
250
Max
5'
300
370
145
650
385
790
465
1080
785
1330
1040
1560
1255
2010
1695
10'
15'
275
580
780
1320
695
20'