Electric door openers
The video door station has a zero-potential relay contact
for a standardised electric door, gate or garage opener
(two wires). There is the possibility of switching on all
electric door openers that work at a maximum power of
1 A in the voltage range of up to 24 V (AC/DC). The video
door station does not provide its own power supply for
the electric door opener. This is provided through the
separate power supply of the electric door opener. You can
learn more about the installation of the power supply
from the instruction manual or technical specifications of
your door opener. Should you have any questions about
this, please contact the manufacturer of your door opener.
You can find compatible electric door opener and a sample
wiring diagram at www.doorbird.com/support
Conventional electric door chime
If someone rings your video door station, you will imme-
diately receive a push notification with sound/vibration
on your smartphone or tablet. In addition the video door
station comes with a zero-potential relay contact for
connecting a conventional electric door chime inside
the building. The relay contact can be used to activate
the separate operating voltage of the door chime or the
door chime via its trigger input. If the operating voltage
of the door chime is activated, it should not be greater
than 24 V (AC/DC). The power consumption should not
exceed 1A. The video door station does not provide its
own power supply for the door chime. This is provided
through the separate power supply of your conventional
door chime. Should you have any questions, please con-
tact the manufacturer of your door chime. You can find
compatible door chimes and a sample wiring diagram at
www.doorbird.com/support
Conventional door opener button
If an electric door opener is connected to the video door
station, the door opener can be opened by App and also
be directly controlled via a zero-potential button to be
found in the interior of the building, i.e. a door opening
button. In addition, the door opener button is to be
connected to the connection terminal provided. Please
make sure to add no extra voltage on that contact. You
can find compatible door opener buttons and a sample
wiring diagram on www.doorbird.com/support
Two insulated
wires.
Two insulated
wires.
Two insulated
wires.